IBM Support

PH33776: GOC - ADD A FIELD TO THE "OPTIONS FOR CHANGE FUNCTIONS" PANEL TO GENERATE DATACHANGED OPTION FOR IDAA

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • GOC - Add a field to the "Options for Change Functions" panel to
    generate DATACHANGED option for IDAA
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of the Db2 Administration Tool and     *
    *                 IDAA.                                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1) Users do not have a way to control   *
    *                      the detectChanges option that is passed *
    *                      to the IDAA stored procedure            *
    *                      SYSPROC.ACCEL_LOAD_TABLES.              *
    *                                                              *
    *                      This APAR provides an enhancement to    *
    *                      specify the detectChanges option.       *
    *                                                              *
    *                      2) CMBATCH allows incompatible IDAA     *
    *                      options to be specified.                *
    ****************************************************************
    1) Users cannot control the IDAA option detectChanges by using
    ADMIN ACCELERATOR LOAD statements in Db2 Admin Tool.
    Admin Tool always sends 'DATA' for this field when calling the
    SYSPROC.ACCEL_LOAD_TABLES stored procedure.
    
    This APAR provides an enhancement to specify the detectChanges
    option.
    
    Panel ADB2PCO, "Options for Change Functions," has been updated
    with the new field "Load accelerated tables DETECTCHANGES."
    This field is described in the help panel:
    
    Specifies the value of detectChanges for the
    SYSPROC.ACCEL_LOAD_TABLES procedure for accelerated tables.
    Possible values are: DATA, PARTITIONS, or NONE.
    
    DATA is the default value. For a description of DATA and
    PARTITIONS, see the information about SYSPROC.ACCEL_LOAD_TABLES
    in the Db2 Analytics Accelerator for z/OS documentation.
    
    NONE indicates that detectChanges is not used when calling
    SYSPROC.ACCEL_LOAD_TABLES.
    
    CMBATCH has also been enhanced to support the new option
    load_accelerated_tables_detect_changes,which accepts the same
    values.
    
    2) Additionally, when using IDAA related options in CMBATCH,
    mutually exclusive values were allowed, causing some changes
    to fail when applied later.
    
    CM Batch now checks the values of IDAA related options,
    similar to panel ADB2PCO. The following rules are enforced:
    
    If either enable_accelerated_tables or
    replicate_accelerated_tables is set to YES, then
    reload_accelerated_tables must also be YES.
    
    If reload_accelerated_tables is set to YES,
    recreate_accelerated_tables must also be YES.
    
    These options default to YES when not specified, so if either
    reload_accelerated_tables or recreate_accelerated_tables is to
    NO by the user, the related options must explicitly be set to
    NO as well, otherwise CMBATCH will issue an error, for example:
    
    ADB9969E ADBCCM  The enable_accelerated_tables action parameter
                      is enabled. This action parameter is conflict
                      with at least one other parameter that is
                      enabled.
    ADB9730I ADBCCM   The following are the values for the action
                      parameters:
                      reload_accelerated_tables = 'N'
    

Problem conclusion

  • The problems have been resolved.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH33776

  • Reported component name

    DB2 OBJECT COMP

  • Reported component ID

    5697G6400

  • Reported release

    C10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-01-25

  • Closed date

    2021-01-29

  • Last modified date

    2021-03-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI73711

Modules/Macros

  • GOCCMP   GOCGCMP
    

Fix information

  • Fixed component name

    DB2 OBJECT COMP

  • Fixed component ID

    5697G6400

Applicable component levels

  • RC10 PSY UI73711

       UP21/02/02 P F102

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"12.1.0"}]

Document Information

Modified date:
06 March 2021