IBM Support

All icons in IBM i2 Analyst's Notebook are represented as a white circle

Troubleshooting


Problem

In IBM i2 Analyst's Notebook, all the icons that are displayed in the "Insert from Palette" are represented by a white circle with black line, instead of their regular, normal icons.
image 7964
None of the icons are displayed correctly.

Cause

The most probable cause is the presence of a corrupted PNG or JPG file in the Custom Icons folder.

Resolving The Problem

  • Go in the Custom Icons folder (should be in My Documents/i2/i2 Shared/Custom Images/Screen/Icons )
  • Check that each PNG and JPG file is correct (try to open each file, and check that it's an image).
  • Also check the dimensions of the pictures. It's recommended to keep them under 256x256 pixels.
  • Remove any JPG or PNG file that is not a valid picture
  • Restart ANB and check that the problem is fixed.
If the custom icons are stored on a network drive (i.e, OneDrive) and you have the same issue. Please check that your network connection is active and you have the correct permissions to the folder/files.

Document Location

Worldwide

[{"Line of Business":{"code":"LOB24","label":"Security Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSXW43","label":"i2 iBase"},"ARM Category":[{"code":"a8m500000008ZHtAAM","label":"i2 iBase and i2 Analyst's WorkStation"}],"ARM Case Number":"TS004574415","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0.x"},{"Type":"MASTER","Line of Business":{"code":"LOB24","label":"Security Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSXUXD","label":"i2 Analyst's Notebook"},"ARM Category":[{"code":"a8m500000008ZHeAAM","label":"i2 Analyst's Notebook"},{"code":"a8m500000008ZHeAAM","label":"i2 Analyst's Notebook"},{"code":"a8m500000008ZHeAAM","label":"i2 Analyst's Notebook"}],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0.0;9.2.0;9.2.4"}]