IBM Support

IJ30402: MMCRNSD FAILED WHEN USING NOT PARTITIONED DASD (DASD ERROR: DISK IN USE)

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • "Disk in use" error when using not partitioned DASD devices.
    DASD '/dev/dasdk' is in use. Unmount it first!
    mmcrnsd: Unexpected error from
    fdasd -a /dev/dasd. Return code: 1
    mmcrnsd: [E] Unable to partition DASD
    device /dev/disk/by-path/ccw-0.0.0500
    mmcrnsd: Failed while processing disk
    stanza on node node01.abc.de
    %nsd: device=/dev/disk/by-path/ccw-0.0.0500
    nsd=scale_data01
    servers=node01.abc.de
    usage=dataAndMetadata
    

Local fix

  • Prior running the mmcrnsd command, partition the
    DASD devices with fdasd -a, refresh the partition
    table on all server nodes, and specify the partitions
    of the devices in the mmcrnsd stanza file.
    Then run the mmcrnsd command.
    

Problem summary

  • "Disk in use" error when using not partitioned DASD devices.
    DASD '/dev/dasdk' is in use. Unmount it first!
    mmcrnsd: Unexpected error from
    fdasd -a /dev/dasd. Return code: 1
    mmcrnsd: [E] Unable to partition DASD
    device /dev/disk/by-path/ccw-0.0.0500
    mmcrnsd: Failed while processing disk
    stanza on node node01.abc.de
    %nsd: device=/dev/disk/by-path/ccw-0.0.0500
    nsd=scale_data01
    servers=node01.abc.de
    usage=dataAndMetadata
    

Problem conclusion

  • Benefits of the solution:
    mmcrnsd runs without the 'Disk in use' problem.
    
    Work around:
    Prior running the mmcrnsd command, partition the
    DASD devices with fdasd -a, refresh the partition
    table on all server nodes, and specify the partitions
    of the devices in the mmcrnsd stanza file.
    Then run the mmcrnsd command.
    
    
    Problem trigger:
    Running the mmcrnsd command on
    not partitioned DASD devices.
    
    Symptom:
    Upgrade/Install failure
    
    Platforms affected:
    s390x-linux only
    
    Functional Area affected:
    Install/Upgrade Toolkit
    
    Customer Impact:
    High Importance
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ30402

  • Reported component name

    SPEC SCALE STD

  • Reported component ID

    5737F33AP

  • Reported release

    505

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-01-22

  • Closed date

    2021-01-22

  • Last modified date

    2021-01-22

  • APAR is sysrouted FROM one or more of the following:

    IJ29815

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SPEC SCALE STD

  • Fixed component ID

    5737F33AP

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY","label":"IBM Spectrum Scale"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"505","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date: