APAR status
Closed as program error.
Error description
Issue while replacing pdisk: [root@ems1 ~]# mmvdisk pdisk replace --prepare --recovery-group rgess08 --pdisk e3d1s38 mmvdisk: Location 78R0914-1-38 contains multiple disk devices. mmvdisk: You cannot use this command to replace disks in the given location. mmvdisk: Location 78R0914-1-38 is Rack RACK7 U16-20, Enclosure 5147-084-78R0914 Drawer 1 Slot 38.
Local fix
Problem summary
mmvdisk --replace command results in message: Location XXX contains multiple disk devices.
Problem conclusion
Benefits of the solution: Code fix allows for disks with unreadable disk descriptor areas to be replaced with the supported manual disk replacement commands. Work Around: Contact IBM support for a workaround disk replacement procedure, or upgrade to a code level with the fix. Problem trigger: The problem happens when hardware errors cause the lower logical block addresses on a disk to become unreadable. Symptom: Error output/message Platforms affected: Linux Only Functional Area affected: ESS/GNR Customer Impact: Suggested:
Temporary fix
Comments
APAR Information
APAR number
IJ30142
Reported component name
SPEC SCALE STD
Reported component ID
5737F33AP
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-01-05
Closed date
2021-01-05
Last modified date
2021-01-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE STD
Fixed component ID
5737F33AP
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY","label":"IBM Spectrum Scale"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"510","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date:
06 January 2021