Error description

  • During MAS shutdown the following message was produced :
    EYUNL0090W applid LMAS is shutting down because it failed to
    become available to process requests
    .
    This message is not expected during MAS shutdown. It would be
    expected to occur during MAS startup if at all.
    .
    Once the MAS was restarted again, it connected fine and all was
    ok.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: Very occasionally the EYUNL0090W        *
    *                      startup message is produced at          *
    *                      shutdown. This is due to race           *
    *                      conditions between CONL and COIE        *
    *                      transactions at both startup and        *
    *                      shutdown.                               *
    ****************************************************************
    * RECOMMENDATION: This fix affects MAS regions and will take   *
    *                 effect from the next MAS restart.            *
    ****************************************************************
    During MAS startup the CONL transaction checks to see if the
    COIE heartbeat transaction has started. This test is repeated
    each time CONL wakes, until the MASINITTIME is reached.
    If the COIE heartbeat task has not started in this time then
    message EYUNL0090W is issued.
    There is a timing window for COIE to go active while the
    CONL task is busy. In this situation CONL can then perform
    the wait code at shutdown and issue EYUNL0090W.
    Additional Keywords: msgEYUNL0090W
    

Problem conclusion

  • The CONL wait for work loop was altered to disable the wait for
    COIE code if the COIE heartbeat was detected.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH30724

  • Reported component name

    CICS TS Z/OS V5

  • Reported component ID

    5655Y0400

  • Reported release

    10M

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-10-20

  • Closed date

    2020-12-22

  • Last modified date

    2021-01-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI73255 UI73256 UI73257

Modules/Macros

  • CJC0NLRT CJD0NLRT CJE0NLRT CJF0NLRT CJG0NLRT CJH0NLRT CJI0NLRT
    EYU0NLRT
    

Fix information

  • Fixed component name

    CICS TS Z/OS V5

  • Fixed component ID

    5655Y0400

Applicable component levels

  • R10M PSY UI73257

       UP20/12/24 P F012

  • R20M PSY UI73256

       UP20/12/24 P F012

  • R30M PSY UI73255

       UP20/12/24 P F012

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4"}]

Document Information

Modified date:
05 January 2021