IBM Support

PH32204: RATE GENERATOR IN RANDOM SELECTOR->WEIGHTED BLOCK OF A SCHEDULE FAILS WITH NULLPOINTEREXCEPTION

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A customer was trying to model a workload that involved running
    various tests at specific rates using a Random Selector with
    Weighted Blocks for each of the tests and then including a Rate
    Generator inside the blocks to control the iteration rate.  When
    they tried this, the tests did not run and each user reported:
    
      java.lang.NullPointerException occurred in <RateGenerator>
    
    Additional experimentation showed that even the simpliest
    schedule with a Rate Generator inside a Weighted Block would
    fail this way.  For example:
    
      User Group 1
        Random Selector (1 block)
          Weighted Block1 (1) (100%)
            Rate Generator (1 iteration): RateGen1
              SomeTest
    

Local fix

  • As a workaround, use a Loop instead of a Rate Generator in the
    schedule.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * RPT Users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See error description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Fixed
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH32204

  • Reported component name

    PERF TESTER WIN

  • Reported component ID

    5724J9601

  • Reported release

    950

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-12-01

  • Closed date

    2023-01-31

  • Last modified date

    2023-01-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    PERF TESTER WIN

  • Fixed component ID

    5724J9601

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSMMM5","label":"Rational Performance Tester"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"950","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
31 January 2023