PH32206: RATE GENERATOR IN COMPOUND TEST IS NOT EXECUTED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A customer added a Rate Generator to a compound test to control
    the iteration rate of a portion of the compound test.  When the
    compound test was executed, the test within the Rate Generator
    was not run while the tests before and after the Rate Generator
    were run as expected.  No errors or warnings were shown in the
    Test Log.
    
    For example, for a compound test containing:
    
      FirstTest
      Rate Generator (3 iterations) RateGen1
        MiddleTest
      LastTest
    
    the execution will run FirstTest and LastTest but not
    MiddleTest.
    

Local fix

  • Use a VU schedule instead of a Compound Test.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * RPT Users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See error description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Fixed
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH32206

  • Reported component name

    PERF TESTER WIN

  • Reported component ID

    5724J9601

  • Reported release

    950

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-12-01

  • Closed date

    2021-07-20

  • Last modified date

    2021-07-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    PERF TESTER WIN

  • Fixed component ID

    5724J9601

Applicable component levels

  • RA02 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSMMM5","label":"Rational Performance Tester"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"950","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
21 November 2021