IBM Support

Physical DataPower Upgrade to 10.0.0.0 / 10.0.1.0 / 2018.4.1.12 / 2018.4.1.13 encounters network issues

Troubleshooting


Problem

When upgrading a physical appliance (non-virtual) to fixpacks 10.0.0.0, 10.0.1.0, 2018.4.1.12 or 2018.4.1.13, unexpected network issues occur.  These range from unexpected timeouts, link loss and/or issues with standby control.

Symptom

The four port 10gb modules interfaces eth20 through eth23 will go link state down.
The switch connected to these four ports may report:
DataPower-5k %ETHPORT-5-IF_DOWN_ERROR_DISABLED: Interface Ethernet1/38 is down (Error disabled. Reason:DCX-No ACK in 100 PDUs)
or
Eth1/40 TEST  dcxNoACKi 203 full 10G 10Gbase-SR
Another method to confirm this is the source of the network outage is simply disable LLDP on the switch port or you could use a command similar to:
show lldp traffic int ethx/xx
If the total frames received does NOT increment then the DataPower eth20/21/22/23 interface is NOT responding and the switch will mark the port down.

Document Location

Worldwide

[{"Line of Business":{"code":"LOB77","label":"Automation Platform"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"ARM Category":[{"code":"a8m50000000CdpRAAS","label":"DataPower-\u003ENetwork (NT)-\u003EEthernet Interface"}],"ARM Case Number":"","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All Version(s)"}]

Log InLog in to view more of this document

This document has the abstract of a technical article that is available to authorized users once you have logged on. Please use Log in button above to access the full document. After log in, if you do not have the right authorization for this document, there will be instructions on what to do next.

Document Information

Modified date:
08 June 2021

UID