IBM Support

IJ29337: POLICY, INODE SCANS AND EA LISTING FAILURES

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • GPFS maintains EA (Extended Attribute) registry to
    verify the EA priority. Due to incorrect
    EA registry addition without
     SG format version check, policy and inode scans
    might fail in the mixed node cluster  environment.
    This problem could occur while running policy
     or inode scans in a mixed node environment
    running with 5.0.5.2 , 5.0.5.3 and 5.1.0.0 and other
    old version nodes as the filesystem manager.
    

Local fix

Problem summary

  • GPFS maintains EA (Extended Attribute) registry to
    verify the EA priority. Due to incorrect
    EA registry addition without
     SG format version check, policy and inode scans
    might fail in the mixed node cluster  environment.
    This problem could occur while running policy
     or inode scans in a mixed node environment
    running with 5.0.5.2 , 5.0.5.3 and 5.1.0.0 and other
    old version nodes as the filesystem manager.
    

Problem conclusion

  • Benefits of the solution:
    Fixed the code to remove incorrect EA registry.
    
    Work around: None
    
    Problem trigger:
    Running policy or inode scans in a mixed node
    cluster environment running with 5.0.5.2 , 5.0.5.3 and
    5.1.0.0 along with older version nodes as the
    filesytsem manager
    
    Symptom: Unexpected results
    
    Platforms affected: All OS environments
    
    Functional Area affected: AFM and FS Core
    
    Customer Impact: Critical
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ29337

  • Reported component name

    SPEC SCALE STD

  • Reported component ID

    5737F33AP

  • Reported release

    505

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-11-19

  • Closed date

    2020-11-19

  • Last modified date

    2020-11-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IJ29356

Fix information

  • Fixed component name

    SPEC SCALE STD

  • Fixed component ID

    5737F33AP

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY","label":"IBM Spectrum Scale"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"505","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
21 November 2020