Error description
When node's hostname is assigned to loopback, mmchnode --quorum -N node causes CCR assertion and even CCR quorum loss. From /var/adm/ras/mmsdrserv.log: [E] /project/spreltac503/build/rtac503s003a/src/avs/fs/mmfs/t s/ccr/ccrutils.C:577: assertion 'ccrNodeId == iter->id' failed Reported In: Spectrum Scale 5.0.2.3 Known Impact: When the problem happens, mmsdrserv cannot startup, which may cause CCR quorum loss.
Local fix
Problem summary
If a hostname is resolved to a loopback address, the CCR component might run into an assertion of type 'ccrNodeId == iter->id' when a node becomes quorum node using the mmchnode or mmaddnode command.
Problem conclusion
Benefits of the solution: No more assert Work around: None Problem trigger: When a node is added as a quorum node and the hostname is resolved to a loopback address. Symptom: Abend/Crash Platforms affected: ALL Operating System environments Functional Area affected: admin commands CCR Customer Impact: High Importance
Temporary fix
Comments
APAR Information
APAR number
IJ29214
Reported component name
SPEC SCALE STD
Reported component ID
5737F33AP
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-11-10
Closed date
2020-11-10
Last modified date
2020-11-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE STD
Fixed component ID
5737F33AP
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY","label":"IBM Spectrum Scale"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"510","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date:
11 November 2020