This SPSS Modeler 18.2.2 Interim Fix1 for Windows, Linux, and Mac fixes several issues with Google BigQuery database. Fixed issues include:
PH31397 MODELER COULD NOT CORRECTLY RECOGNIZE BIG QUERY'S NUMERIC DATA TYPE.
PH31392 SQL VALIDATION ERROR OCCURRED WHEN USING DATETIME_DATE() FUNCTION AGAINST BIG QUERY DATABASE.
PH31393 SQL PUSHBACK AGAINST BIG QUERY FAILED WHEN USING SOME NUMERIC FUNCTIONS.
PH31391 SQL PUSH-BACK FAILED WHEN USING @TODAY, DATETIME_NOW AND DATETIME_IN_SECONDS FUNCTIONS AGAINST BIG QUERY DATABASE
This Interim Fix can only be installed over existing installations of IBM SPSS Modeler 18.2.2 on Windows, Mac, and Linux64.
- IBM SPSS Modeler Client 18.2.2.0
- IBM SPSS Modeler Server 18.2.2.0
Interim Fix applied over IBM SPSS Modeler Server 18.2.2 and IBM SPSS Modeler Client 18.2.2
----------------------------------------
BY DOWNLOADING, INSTALLING, COPYING, ACCESSING, OR OTHERWISE USING THE SOFTWARE, YOU AGREE TO THE TERMS OF THE SPSS LICENSE AGREEMENT UNDER WHICH YOU ACQUIRED IBM SPSS Modeler.
BY AGREEING, YOU REPRESENT AND WARRANT THAT YOU HAVE FULL AUTHORITY TO ACCEPT THESE TERMS. IF YOU DO NOT AGREE TO THESE TERMS,
- DO NOT DOWNLOAD, INSTALL, COPY, ACCESS, OR USE THE SOFTWARE; AND
- PROMPTLY RETURN THE UNUSED MEDIA AND DOCUMENTATION TO THE PARTY FROM WHOM IT WAS OBTAINED. IF THE SOFTWARE WAS DOWNLOADED, DESTROY ALL COPIES OF THE SOFTWARE.
Affected Modules:
-----------------
For windows:
[INSTALLDIR]\bin\modelerserver.exe
[INSTALLDIR]\config\ContainerFile.bin
For Mac:
[INSTALLDIR]\modelerserver
[INSTALLDIR]\config\ContainerFile.bin
For Linux:
[INSTALLDIR]\modelersrv_18_2
[INSTALLDIR]\config\ContainerFile.bin
Installation Instructions:
--------------------------
1) Shut down Modeler Client/Server.
2) Replace the files with those in the .zip file:
2.1) Unzip the interim fix into a temporary folder.
2.2) Navigate to the Installation folder where you will find the affected file:
2.3) To make a back up of the file, move it to a temporary folder outside of the [INSTALLDIR] folder.
2.4) Move the extracted files from step 2.1 into corresponding folder above to replace the old file.
3) Restart Modeler Client/Server.
Un-install Instructions:
--------------------------
1) Shut down Modeler Client/Server.
2) Replace the following files with those in the backup folder:
2.1) Navigate to the Installation folder and delete affected file listed above:
2.2) Copy files from the back up folder in step 2.3 of the installation instructions to replace affected files.
3) Restart Modeler Client/Server.
On
[{"DNLabel":"18.2.2.0-IM-S18MODELER-WIN64-IF001","DNDate":"10 Nov 2020","DNLang":"Language Independent","DNSize":"3119 KB","DNPlat":{"label":"Windows","code":"PF033"},"DNURL":"http://www.ibm.com/support/fixcentral/quickorder?product=ibm%2FInformation+Management%2FSPSS+Modeler&fixids=18.2.2.0-IM-S18MODELER-WIN64-IF001&source=SAR","DNURL_FTP":"","DDURL":null},{"DNLabel":"18.2.2.0-IM-S18MODELER-LINUX64-IF001","DNDate":"10 Nov 2020","DNLang":"Language Independent","DNSize":"4156 KB","DNPlat":{"label":"Linux","code":"PF016"},"DNURL":"http://www.ibm.com/support/fixcentral/quickorder?product=ibm%2FInformation+Management%2FSPSS+Modeler&fixids=18.2.2.0-IM-S18MODELER-LINUX64-IF001&source=SAR","DNURL_FTP":"","DDURL":null},{"DNLabel":"18.2.2.0-IM-S18MODELER-MAC-IF001","DNDate":"10 Nov 2020","DNLang":"Language Independent","DNSize":"3075 KB","DNPlat":{"label":"Mac OS","code":"PF017"},"DNURL":"http://www.ibm.com/support/fixcentral/quickorder?product=ibm%2FInformation+Management%2FSPSS+Modeler&fixids=18.2.2.0-IM-S18MODELER-MAC-IF001&source=SAR","DNURL_FTP":"","DDURL":null}]
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3RA7","label":"IBM SPSS Modeler"},"ARM Category":[{"code":"a8m500000008hBRAAY","label":"Modeler->Documentation"}],"ARM Case Number":"","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"18.2.2"}]