APAR status
Closed as program error.
Error description
mmhealth cluster show: faster heartbeat_missing
Local fix
Running "mmhealth config interval high" would have a similar effect on heartbeat events but at a cost of a lot of system resources
Problem summary
mmhealth cluster show: faster heartbeat_missing
Problem conclusion
Benefits of the solution: If network issues arise, mmhealth will report it much faster with this fix. Work Around: Running "mmhealth config interval high" would have a similar effect on heartbeat events but at a cost of a lot of system resources Problem trigger: network outage Symptom: Network Outage Platforms affected: ALL Linux OS environments + AIX Functional Area affected: System Health Customer Impact: Suggested
Temporary fix
Comments
APAR Information
APAR number
IJ29045
Reported component name
SPEC SCALE STD
Reported component ID
5737F33AP
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-11-06
Closed date
2020-11-06
Last modified date
2020-11-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE STD
Fixed component ID
5737F33AP
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY","label":"IBM Spectrum Scale"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"510","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date:
07 November 2020