APAR status
Closed as program error.
Error description
mmhealth does not work on AIX
Local fix
1. touch mmsysmon.json 2. mmccr fput mmsysmon.json mmsysmon.json 3. mmdsh -N all mmsysmoncontrol restart After this workaround Sysmonitor will be able to startup, but some of its features (e.g. hiding events) will stay broken.
Problem summary
mmhealth does not work on AIX
Problem conclusion
Benefits of the solution: mmhealth command and all other Spectrum Scale components, that rely on it, will work. Work Around: 1. touch mmsysmon.json 2. mmccr fput mmsysmon.json mmsysmon.json 3. mmdsh -N all mmsysmoncontrol restart After this workaround Sysmonitor will be able to startup, but some of its features (e.g. hiding events) will stay broken. Problem trigger: All new Spectrum Scale installations on AIX 7.1 and AIX 7.2 are generally affected in a major way (Sysmonitor cannot startup). Upgraded installations have some degraded functions. Symptom: Component Level Outage Platforms affected: AIX/Power only Functional Area affected: System Health Customer Impact: Critical Changed Externals: none
Temporary fix
Comments
APAR Information
APAR number
IJ28889
Reported component name
SPEC SCALE STD
Reported component ID
5737F33AP
Reported release
505
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-10-29
Closed date
2020-10-29
Last modified date
2020-10-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE STD
Fixed component ID
5737F33AP
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY","label":"IBM Spectrum Scale"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"505","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date:
10 November 2020