APAR status
Closed as program error.
Error description
On file system with HAWC enabled, data written to disk could be lost after a node failure when using the system call fdatasync() or Ganesha.
Local fix
Disable HAWC or avoid using the system call fdatasync() to flush the data to disk
Problem summary
On file system with HAWC enabled, data written to disk could be lost after a node failure when using the system call fdatasync() or Ganesha.
Problem conclusion
Benefits of the solution: Prevent lost data written to disk. Work Around: Disable HAWC or avoid using the system call fdatasync() to flush the data to disk Problem trigger: Node failure such as file system panic, quorum loss, etc with HAWC enabled file system Symptom: Unexpected Results/Behavior Platforms affected: ALL Operating System environments Functional Area affected: HAWC Customer Impact: Critical
Temporary fix
Comments
APAR Information
APAR number
IJ28849
Reported component name
SPEC SCALE STD
Reported component ID
5737F33AP
Reported release
505
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-10-27
Closed date
2020-10-27
Last modified date
2020-10-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE STD
Fixed component ID
5737F33AP
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY","label":"IBM Spectrum Scale"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"505","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date: