IBM Support

IJ28849: POSSIBLE DROPPED WRITE AFTER A NODE FAILURE ON A FILE SYSTEM WITH HAWC ENABLED.

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • On file system with HAWC enabled, data written
    to disk could be lost after a node failure when using
    the system call fdatasync() or Ganesha.
    

Local fix

  • Disable HAWC or avoid using the system call
    fdatasync() to flush the data to disk
    

Problem summary

  • On file system with HAWC enabled, data written
    to disk could be lost after a node failure when using
    the system call fdatasync() or Ganesha.
    

Problem conclusion

  • Benefits of the solution:
    Prevent lost data written to disk.
    
    Work Around:
    Disable HAWC or avoid using the system call
    fdatasync() to flush the data to disk
    
    Problem trigger:
    Node failure such as file system panic,
    quorum loss, etc with HAWC enabled file system
    
    Symptom:
    Unexpected Results/Behavior
    
    Platforms affected:
    ALL Operating System environments
    
    Functional Area affected:
    HAWC
    
    Customer Impact:
    Critical
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ28849

  • Reported component name

    SPEC SCALE STD

  • Reported component ID

    5737F33AP

  • Reported release

    505

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-10-27

  • Closed date

    2020-10-27

  • Last modified date

    2020-10-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SPEC SCALE STD

  • Fixed component ID

    5737F33AP

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY","label":"IBM Spectrum Scale"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"505","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
28 October 2020