A fix is available
APAR status
Closed as program error.
Error description
A reorg job generated by Database Control Suite with a CCF step to DBR the database goes into a wait because the DD statement for the database has DISP=OLD and the database is still allocated to the IMS online system.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: ALL CONTROL SUITE R3.10 USERS * **************************************************************** * PROBLEM DESCRIPTION: THE REORG JOB WHICH IS GENERATED WITH * * A CCF STEP TO /DBR THE DATABASE GOES * * INTO A WAIT BECAUSE THE DISP=OLD IS * * CODED IN THE REORG STEPS. * **************************************************************** * RECOMMENDATION: * **************************************************************** THE REORG JOB WHICH IS GENERATED WITH THE CCF OPTIONAL JOB STEP WHICH WILL SUBMIT THE /DBR COMMAND TO CLOSE THE DATABASE GOES INTO A WAIT BECAUSE THE DISP=OLD IS CODED ON THE DD STATEMENTS FOR THE DATABASE IN THE REORG STEPS.
Problem conclusion
MODIFY CCF SUPPORT FOR REORG'S, TO CREATE TWO SEPARATE JOBS TO BE SUBMITTED CONCURRENTLY. MODIFY CCF JCL GENERATION TO INCLUDE DYNAMIC ALLOCATION LIBRARY DATA DEFINITION STATEMENT.
Temporary fix
Comments
APAR Information
APAR number
PK00558
Reported component name
IMS DB CNTL SUI
Reported component ID
5655F7600
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2005-02-03
Closed date
2005-02-14
Last modified date
2005-03-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK00552
Modules/Macros
IDLCCF01 IDLCCF02 IDLC0001 IDLGNJCX
Fix information
Fixed component name
IMS DB CNTL SUI
Fixed component ID
5655F7600
Applicable component levels
R310 PSY UK00552
UP05/02/16 P F502
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88W","label":"IMS Database Control Suite"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310"}]
Document Information
Modified date:
22 October 2020