A fix is available
APAR status
Closed as program error.
Error description
When IPR Unload utility is running with IMS compatible JCL and APF-authorized STEPLIB libraries, an ABENDS0C4 occurs in FABHRTI0+X'700'.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS High Performance Unload for * * z/OS, Version 1 Release 2 (FMID=H1IN120), * * who use the IPR Unload utility of IMS * * Parallel Reorganization for z/OS Version 3 * * Release 2 (FMID=H25N320). * **************************************************************** * PROBLEM DESCRIPTION: If you use a JCL that is written for * * IMS HD Reorganization Unload to run * * the IPR Unload utility and the * * JOBLIB/STEPLIB are APF-authorized, * * IPR Unload gets ABEND0C4 at FABHRTI0. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** If you use a JCL that is written for IMS HD Reorganization Unload (DFSURGU0) to run the IPR Unload utility and the JOBLIB/STEPLIB are APF-authorized, IPR Unload gets ABEND0C4 at FABHRTI0+X'700'. The module FABHRTI0 updated the data save area defined in the reentrant load module.
Problem conclusion
The module FABHRTI0 has been modified not to update the data save area of the module FABHINI0.
Temporary fix
Comments
APAR Information
APAR number
PK65851
Reported component name
IMS HIGHPERF UN
Reported component ID
5655E0600
Reported release
120
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-05-09
Closed date
2008-05-28
Last modified date
2008-06-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK36870
Modules/Macros
FABHINI0 FABHRTI0
Fix information
Fixed component name
IMS HIGHPERF UN
Fixed component ID
5655E0600
Applicable component levels
R120 PSY UK36870
UP08/05/30 P F805
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSCX89K","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0"}]
Document Information
Modified date: