A fix is available
APAR status
Closed as program error.
Error description
WLR V2.5 does not route transactions when PRCHNG/PRISRT calls are made and no PRCHNG/PRISRT entry points are provided in the DFSMSCE0 exit when executing under IMS V8 and V9.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Workload Router V2.5 * * with IMS V8 or IMS V9. * **************************************************************** * PROBLEM DESCRIPTION: Transactions not routed when * * PRCHNG/PRISRT calls are made * * executing under IMS V8 and V9. * **************************************************************** * RECOMMENDATION: * **************************************************************** WLR V2.5 does not route transactions when PRCHNG/PRISRT calls are made and no PRCHNG/PRISRT entry points are provided in the DFSMSCE0 exit when executing under IMS V8 and V9. Workload Router does not receive control for PRCHNG or PRISRT calls if a customized DFSMSEC0 exit does not include the PRCHNG/PRISRT entry points.
Problem conclusion
Part IWXMSCE1 has been modified to correct this problem.
Temporary fix
Comments
APAR Information
APAR number
PK91716
Reported component name
IMS WLR
Reported component ID
5697B8700
Reported release
250
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2009-07-17
Closed date
2009-07-22
Last modified date
2009-08-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK48600 UK48601
Modules/Macros
IWXMSCE1
Fix information
Fixed component name
IMS WLR
Fixed component ID
5697B8700
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSCX8AD","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.5.0"}]
Document Information
Modified date: