IBM Support

PK91716: TRANSACTIONS NOT ROUTED WHEN PRCHNG/PRISRT CALLS ARE MADE EXECUTING UNDER IMS V8 AND V9.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • WLR V2.5 does not route transactions when PRCHNG/PRISRT calls
    are made and no PRCHNG/PRISRT entry points are provided in the
    DFSMSCE0 exit when executing under IMS V8 and V9.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Workload Router V2.5                *
    *                 with IMS V8 or IMS V9.                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: Transactions not routed when            *
    *                      PRCHNG/PRISRT calls are made            *
    *                      executing under IMS V8 and V9.          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    WLR V2.5 does not route transactions when PRCHNG/PRISRT calls
    are made and no PRCHNG/PRISRT entry points are provided in the
    DFSMSCE0 exit when executing under IMS V8 and V9.
    Workload Router does not receive control for PRCHNG or PRISRT
    calls if a customized DFSMSEC0 exit does not include the
    PRCHNG/PRISRT entry points.
    

Problem conclusion

  • Part IWXMSCE1 has been modified to correct this problem.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK91716

  • Reported component name

    IMS WLR

  • Reported component ID

    5697B8700

  • Reported release

    250

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2009-07-17

  • Closed date

    2009-07-22

  • Last modified date

    2009-08-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK48600 UK48601

Modules/Macros

  •    IWXMSCE1
    

Fix information

  • Fixed component name

    IMS WLR

  • Fixed component ID

    5697B8700

Applicable component levels

  • R250 PSY UK48600

       UP09/07/24 P F907

  • R253 PSY UK48601

       UP09/07/24 P F907

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSCX8AD","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.5.0"}]

Document Information

Modified date:
20 October 2020