APAR status
Closed as program error.
Error description
getInode() resets pcacheCtlAttribute if pcache is not enabled. Pcache is not enabled for secondary mode filesets. Check for CTL attr only if the CTL attribute was already set in getInode(). pcacheCtlAttribute is set during the file open if the CTL attr is found in the inode.
Local fix
Problem summary
AFM uses special control files to replicate ACLs, EAs and to check fileset mode at the home/secondary site. This special control file is not being recognized correctly thus affecting the EA and ACLs replication and fileset mode recognition.
Problem conclusion
Benefits of the solution: EAs and ALCs replicate correctly. Fileset mode recognized. Work around: None. Problem trigger: AFM and AFM DR replication. Symptom: Unexpected results. Platforms affected: All Linux OS environments. Functional Area affected: AFM and AFM DR. Customer Impact: HiPER
Temporary fix
Comments
APAR Information
APAR number
IJ28611
Reported component name
SPEC SCALE ADV
Reported component ID
5737F35AP
Reported release
505
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-10-07
Closed date
2020-10-12
Last modified date
2020-10-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE ADV
Fixed component ID
5737F35AP
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY","label":"IBM Spectrum Scale"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"505","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date:
13 October 2020