Error description
afmFastCreate when set doesn't filter create messages already in the queue when remove comes in. As a result both a create and a remove on same file can exist on the queue at the same time. If a Link gets sandwiched between the create and the remove then the Link fails to find the remote file and sees it as a conflict and drops the queue. Causing resync + recovery later to complete the sync.
Local fix
Problem summary
afmFastCreate when set doesn't filter create messages already in the queue when remove comes in. As a result both a create and a remove on same file can exist on the queue at the same time. If a Link gets sandwiched between the create and the remove then the Link fails to find the remote file and sees it as a conflict and drops the queue. Causing resync + recovery later to complete the sync.
Problem conclusion
Benefits of the solution: Queue doesn't get dropped and this unwanted recovery + resync is not triggered for the fileset. Ability to replicate the captured queue as is for AFM. Work Around: None today. Problem trigger: Run a lot of temporary file generating workloads on a SW/DR Primary fileset with afmFastCreate on. During the temporary files getting generated and removed, a link should be created as well. Symptom: Unexpected Behavior. Platforms affected: ALL Linux OS environments. Functional Area affected: AFM and AFM ADR Customer Impact: High Importance
Temporary fix
Comments
APAR Information
APAR number
IJ28607
Reported component name
SPEC SCALE STD
Reported component ID
5737F33AP
Reported release
505
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-10-08
Closed date
2020-10-08
Last modified date
2020-10-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE STD
Fixed component ID
5737F33AP
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY","label":"IBM Spectrum Scale"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"505","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date:
09 October 2020