A fix is available
APAR status
Closed as program error.
Error description
ABEND0C4 may occur when all of the following conditions are met: - Using Load API. - Multiple DBPCBs are defined in the PSB and the DBPCB for the second and subsequent HALDBs as the DBPCB used by HP Load. - There are segments with segment edit/compression routine specified with the INIT option on the first DBPCB and the DBPCB for HP Load. - The application program issues an ISRT call to the HP Load DBPCB first.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM IMS High Performance Load * * for z/OS Version 2 Release 1 (FMID=H1IM210). * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C4 may occur when all of the * * following conditions are met: * * - Using Load API. * * - Multiple DBPCBs are defined in the * * PSB and the DBPCB for the second and * * subsequent HALDBs as the DBPCB used * * by HP Load. * * - There are segments with segment * * edit/compression routine specified * * with the INIT option on the first * * DBPCB and the DBPCB for HP Load. * * - The application program issues an * * ISRT call to the HP Load DBPCB first. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** ABEND0C4 may occur when all of the following conditions are met: - Using Load API. - Multiple DBPCBs are defined in the PSB and the DBPCB for the second and subsequent HALDBs as the DBPCB used by HP Load. - There are segments with segment edit/compression routine specified with the INIT option on the first DBPCB and the DBPCB for HP Load. - The application program issues an ISRT call to the HP Load DBPCB first. HP Load mistakenly sets the address of the segment edit/compression routine in the IMS control block for a DBPCB other than the DBPCB for HP Load.
Problem conclusion
HP Load has been modified to sets the address of the segment edit/compression routine in the IMS control block correctly.
Temporary fix
Comments
APAR Information
APAR number
PH30311
Reported component name
IMS HP LOAD
Reported component ID
5655E0700
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-10-07
Closed date
2020-10-19
Last modified date
2022-09-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI72126
Modules/Macros
HPSRHAL2 HPSRHAL3 HPSRHAL4 HPSRHAL5 HPSRHAL7 HPSRHAL8 HPSRHAL9 HPSRHALA HPSRHALB
Fix information
Fixed component name
IMS HP LOAD
Fixed component ID
5655E0700
Applicable component levels
R210 PSY UI72126
UP20/10/21 P F010
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89F","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0"}]
Document Information
Modified date: