IBM Support

PK63957: THIS APAR FIXES SEVERAL HPIC ERRORS.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • This APAR fixes several HPIC errors found during testing.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 4 Release 1 users ( FMID=H1J0410 )   *
    ****************************************************************
    * PROBLEM DESCRIPTION: HPIC V4R1 under IMS Database Recovery   *
    *                      Facility has following two problems:    *
    *                      - NOTIFY.IC command fails with          *
    *                        message DSP0204I ( MSGDSP204I ) .     *
    *                        Because HPIC does not correctly       *
    *                        convert the TIMESTAMP Zone offset     *
    *                        value. Then NOTIFY.IC command fails   *
    *                        with using the incorrect TIMESTAMP.   *
    *                                                              *
    *                      - DRF terminates with                   *
    *                        'VOLSER COUNT ERROR' WTO message and  *
    *                        ABEND U0384 (ABENDU0384) .            *
    *                        HPIC returns to DRF with error return *
    *                        code, when a value of VOLSER2 is not  *
    *                        correct even if only primary IC is    *
    *                        requested by DRF.                     *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    HPIC V4R1 under IMS Database Recovery Facility has following two
    problems:
    - NOTIFY.IC command fails with message DSP0204I ( MSGDSP204I ) .
      Because HPIC dose not correctly convert the TIMESTAMP Zone
      offset value. Then NOTIFY.IC command fails with using the
      incorrect TIMESTAMP.
    
    - DRF terminates with 'VOLSER COUNT ERROR' WTO message and
      ABEND ( ABENDU0384 ) .
      HPIC returns to DRF with error return code, when a value of
      VOLSER2 is not correct even if secondary IC is not requested
      by DRF. HPIC should not build the VOLSER2 keyword when only
      primary IC is requested by DRF.
    

Problem conclusion

  • FABJDRQS has been modified to convert the TIMESTAMP offset value
    correctly.
    
    FABJINT3 has been modified not to build the VOLSER2 keyword when
    only primary IC requested by DRF and not to issue 'VOLSER COUNT
    ERROR' WTO message.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK63957

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-04-04

  • Closed date

    2008-04-24

  • Last modified date

    2008-06-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK35842

Modules/Macros

  •    FABJDRQS FABJINT3
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R410 PSY UK35842

       UP08/05/03 P F805

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89E","label":"IMS HP Image Copy"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1.0"}]

Document Information

Modified date: