PI28972: ABEND0C7 COMCSUTC X'22C' WHEN INCORRECT IMS VERSION IS USED AND ROLL-UP OF INTERNAL ISSUES - SEE ERROR DESC FOR DETAILS

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • 1) ABENDS0C7 COMCSUTC+22C formatting UTC time with incorrect
    IMS version (e.g. IMS V10 or V11 logs utilized with IMS
       V13 being specified to IMSPI).                           S0C7
    2) IMS Connect have added XCF group to the Datastore Information
       Block (DSIB), so we're adding support for this.
    3) IMS Connect have added IRM extensions for Password Phrase,
       Context and Tracking ID, so we're adding support for this.
    4) The IMS Connect A9 XML trace record can be difficult to
       interpret, so improvements are being made.
    5) FORMAT(BRIEF) does not display UTC in report, which we will
       correct here.
    

Local fix

  • For item #1, specify the correct IMS Release for individual log
    files.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Problem Investigator V2.3       *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND0C7 COMCSUTC X'22C' when incorrect *
    *                      IMS version is used. Also roll-up of    *
    *                      internal issues                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    This APAR addresses the following issues:
    1.IMS Connect have added XCF group to the Datastore Information
      Block (DSIB).
    2.IMS Connect have added IRM extensions for Password Phrase,
      Context and Tracking ID.
    3.The IMS Connect A9 XML trace record can be difficult to
      interpret.
    4.Abend S0C7 COMCSUTC+22C formatting UTC time with incorrect
      IMS version.
    5.FORMAT(BRIEF) does not display UTC in report.
    

Problem conclusion

  • The following changes have been made for the above issues:
    1.Added support for changes to the DSIB used in IMS Connect
      knowledge modules.
    2.Added support for IRM extensions.
    3.Improvements to the formatting of the IRM and RXML sections of
      the IMS Connect A9 XML trace record.
    4.Additional validation performed before passing UTC timestamps
      for formatting.
    5.Display UTC in FORMAT(BRIEF) report output.
    

Temporary fix

  • 
    

Comments

  • 
    

APAR Information

  • APAR number

    PI28972

  • Reported component name

    IMS PROBLEM INV

  • Reported component ID

    5655K5000

  • Reported release

    230

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-11-04

  • Closed date

    2014-11-17

  • Last modified date

    2014-12-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI23121

Modules/Macros

  •    ALZA0A19 ALZA0A49 ALZA0A99 ALZA0109 ALZA07C9
    ALZBRAPI ALZLCAT  ALZLRFIL ALZ2910A ALZ2910B ALZ2910C ALZ2910D
    ALZ29109 ALZ50A   ALZ50B   ALZ50C   ALZ50D   ALZ509   ALZ53A
    ALZ53B   ALZ53C   ALZ53D   ALZ539   ALZ5947A ALZ5947B ALZ5947C
    ALZ5947D ALZ59479 ALZ5950A ALZ5950B ALZ5950C ALZ5950D ALZ59509
    ALZ5955A ALZ5955B ALZ5955C ALZ5955D ALZ59559
    

Fix information

  • Fixed component name

    IMS PROBLEM INV

  • Fixed component ID

    5655K5000

Applicable component levels

  • R230 PSY UI23121

       UP14/11/19 P F411

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A4","label":"IMS Problem Investigator"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"230"}]

Document Information

Modified date:
02 April 2021