IBM Support

PM81036: REMOVE INTERFACE PARAMETER NUMBER CHECK AND SUPPORT MULTIPLE "INIT(INID)...EOF" CALLS FOR FABCUR7

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • Adjust FABCUR7 to not check the number of interface parameter(s)
    and to support multiple "INIT(INID)...EOF" calls for FABCUR7.
    
    This is a forward fit of FPSP V1R1 APAR PM72627.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users who use HPFPU DEDB Unloaded        *
    *                 Segment Data Set Retrieve utility (FABCUR7)  *
    *                 in Fast Path Solution Pack Version 1         *
    *                 Release 2 (FMID: HAHQ120).                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: Forward Fit APAR of FPSP V1R1 PM72627:  *
    *                      1. Remove the checking of the number of *
    *                         application interface parameter(s)   *
    *                         in FABCUR7.                          *
    *                      2. Support the multiple "INIT(INID)...  *
    *                         EOF" calls for FABCUR7.              *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    Forward Fit APAR of FPSP V1R1 PM72627:
    This APAR addresses the following enhancements:
    1. FABCUR7 ignores the extra parameter(s) in the interface
       parameter list.
    2. FABCUR7 allows multiple "INIT(INID)-GET(GET1/GET2)-EOF"
       calls, which means that FABCUR7 continues to process if
       INIT (INID) call is issued after the EOF call.
    

Problem conclusion

Temporary fix

Comments

  • ========================
    = DOCUMENTATION CHANGE =
    ========================
    The IMS Fast Path Solution Pack for z/OS Version 1 Release 2
    IMS High Performance Fast Path Utilities User's Guide
    (SC19-3287-00).
    
    5.0 Supplementary utilities
     5.5 DEDB Unloaded Segment Data Set Retrieve utility
      5.5.3 Calling the DEDB Unloaded Segment Data Set Retrieve
            utility (from your program)
       5.5.3.3 Application interface
    
    The following description should be added before
    "Initialization functions: INIT/INID":
    
     | FABCUR7 allows multiple "INIT(INID)-GET(GET1/GET2)-EOF"
     | calls, which means that FABCUR7 continues to process if
     | INIT (INID) call is issued after the EOF call.
    
    The following description should be deleted:
    
    Note: The INIT or INID function must be run prior to any other
    function call.
    
      5.5.7 Examples for the DEDB Unloaded Segment Data Set Retrieve
            utility
    Figure 360. COBOL statements for using FABCUR6 and FABCUR7
               (Part 2 of 2)
    The following codes should be modified:
    
       * -------------------------------------------------------- *
       * -----        INITIALIZATION PROCESSING     ------------- *
       * -------------------------------------------------------- *
        INIT_PROC.
            CALL    'FABCUR7'         USING FUNC_INIT.
            CALL    'FABCUR6'         USING FUNC_INIT,
                                            UR6_DBDNAME.
     | * -- CLEAR STATUS CODE FOR THE NEXT GET CALL. --*
     |      MOVE     STATUS-OK        TO STATUS-CODE.
        INIT_PROC_END. EXIT.
    

APAR Information

  • APAR number

    PM81036

  • Reported component name

    IMS FP SOLUTION

  • Reported component ID

    5655W1400

  • Reported release

    120

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2013-01-21

  • Closed date

    2013-01-24

  • Last modified date

    2013-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK91173

Modules/Macros

  •    FABCUR7X FABC7EOF FABC7GET FABC7INI
    

Publications Referenced
SC19328700    

Fix information

  • Fixed component name

    IMS FP SOLUTION

  • Fixed component ID

    5655W1400

Applicable component levels

  • R120 PSY UK91173

       UP13/01/26 P F301

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCV35A","label":"IMS Fast Path Solution Pack"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0"}]

Document Information

Modified date: