A fix is available
APAR status
Closed as program error.
Error description
In IMS PA V4.1 the CPUTIME data provided by the IMS X'07' record is in Timer Units, which is converted to Micro-second numbers in the Transaction History extract. In IMS PA V4.2 the CPUTIME data is provided in Micro-seconds, but the same conversion factor is still being applied in the Transaction History extract. The CPUTIME conversion factor is no longer required.
Local fix
Conversion factor is to divide by 26.04166 in case anyone needs to make any conversion by hand.
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Performance Analyzer V4.2 * **************************************************************** * PROBLEM DESCRIPTION: Inflated CPUTIME numbers in Transaction * * History extract. * **************************************************************** * RECOMMENDATION: * **************************************************************** In IMS PA V4.1 the CPUTIME data provided by the IMS X'07' record is in Timer Units, which is converted to Micro-second numbers in the Transaction History extract. In IMS PA V4.2 the CPUTIME data is provided in Micro-seconds, but the same conversion factor is still being applied in the Transaction History extract. Also, we removed the dynamic allocation of IPIDIAGS.
Problem conclusion
Conversion of CPUTIME data is no longer required in the Transaction History extract.
Temporary fix
Comments
APAR Information
APAR number
PM06000
Reported component name
IMS PERF ANALYZ
Reported component ID
5655E1500
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2010-01-25
Closed date
2010-02-01
Last modified date
2010-03-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK54051
Modules/Macros
IPICXJCG IPICXJCI IPIGINIT IPIRSJSK IPISAPAR IPISTH00
Fix information
Fixed component name
IMS PERF ANALYZ
Fixed component ID
5655E1500
Applicable component levels
R420 PSY UK54051
UP10/02/04 P F002
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A2","label":"IMS Performance Analyzer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"420"}]
Document Information
Modified date:
14 December 2020