A fix is available
APAR status
-
Closed as program error.
Error description
-
When LIU DBD Map Viewer (FABXGMAP) is scheduled from IBM Management Console more than one time, the message, ICH408I RACF validation errors on temporary data sets, occurs in a DAI SOT address space STC. After the RACF validation errors, ABEND 0C4 or 913 occurs. This problem happens at the second running of DBD Map Viewer in the DAI SOT address space.
Local fix
Problem summary
-
**************************************************************** * USERS AFFECTED: IMS Library Integrity Utilities for z/OS, * * Version 2 Release 2 (FMID=H27P220) users who * * use DBD Map Viewer in IBM Tools Base for * * z/OS Administration Console or IBM * * Management Console for IMS and DB2 for z/OS. * **************************************************************** * PROBLEM DESCRIPTION: When LIU DBD Map Viewer (FABXGMAP) is * * scheduled more than one time from IBM * * Administration Console or IBM * * Management Console, the message, * * ICH408I RACF validation errors on * * temporary data sets, is issued in a * * DAI SOT address space STC. * * * * ICH408I USER(xxxxx) GROUP(xxxxx) * * NAME(xxxxx) a temporary data set name * * CL(xxxxx ) VOL(xxxxx) * * INSUFFICIENT ACCESS AUTHORITY * * ACCESS INTENT(ALTER ) * * ACCESS ALLOWED(NONE ) * * * * After the RACF validation errors, ABEND * * 0C4 occurs. * * * * Continuously, another ICH408I message * * appears. * * ICH408I USER(xxxxx) GROUP(xxxxx) * * NAME(xxxxx) a temporary data set name * * CL(xxxxx) VOL(xxxxx) * * INSUFFICIENT ACCESS AUTHORITY * * ACCESS INTENT(READ ) * * ACCESS ALLOWED(NONE ) * * * * This time, ABEND 913 occurs after the * * ICH408I message. * * * * This problem happens * * at the second running of DBD Map Viewer * * in the DAI SOT address space. * **************************************************************** * RECOMMENDATION: * **************************************************************** The root cause of the problems is LIU FABXGMAP does not delete the temporary data sets. When IBM Tools Base DAI managing an IMS Tools product task in the SOT address space, DAI removes RACF environment before terminating the task. Therefore, the IMS Tools product task should delete the temporary resources before it terminates and allocate new temporary resources at the second run in the SOT. However, when FABXGMAP runs in the SOT address space, it allocates some temporary data sets dynamically which are FABNSYSI, FABNSYSO, SYSPRINT and FABNSYSP but does not delete them. After that, when FABXGMAP runs at the second time in the SOT address space, FABXGMAP attempts to delete the temporary data sets previously allocated. However, the user ID is not authorized to access the former temporary data sets, because the previous RACF environment has been removed. As the result, the first ICH408I error occurs. The subsequent 0C4 abend is caused by accessing the data set failed. Another ICH408I error and ABEND913 occur because the temporary data sets has not been deleted at the end of first FABXGMAP run, too.
Problem conclusion
-
The following modules have been modified. FABLINT0,FABXGMAP
Temporary fix
Comments
APAR Information
-
APAR number
PI32729
-
Reported component name
IMS LIBR INTEG
-
Reported component ID
5655I4200
-
Reported release
220
-
Status
CLOSED PER
-
PE
NoPE
-
HIPER
NoHIPER
-
Special Attention
NoSpecatt / Xsystem
-
Submitted date
2015-01-14
-
Closed date
2015-02-10
-
Last modified date
2015-03-03
-
APAR is sysrouted FROM one or more of the following:
-
APAR is sysrouted TO one or more of the following:
UI25049
Modules/Macros
-
FABLINT0 FABXGMAP
Fix information
-
Fixed component name
IMS LIBR INTEG
-
Fixed component ID
5655I4200
Applicable component levels
-
R220 PSY UI25049
UP15/02/13 P F502
Fix is available
-
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89N","label":"IMS Library Integrity Utilities"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220"}]
Document Information
Modified date: