A fix is available
APAR status
-
Closed as unreproducible in next release.
Error description
-
MSGHPSR0003W LAST RECORD WAS NOT A TRAILER RECORD received. File was determined to be *HD format because of information in the header record. However, the format was actually *CS and the spec for *CS needs to be revised.
Local fix
Problem summary
-
**************************************************************** * USERS AFFECTED: All users of IBM IMS High Performance * * Load for OS/390 Release 1 (FMID=H1IM110). * **************************************************************** * PROBLEM DESCRIPTION: HP Load utility gets MSGHPSR0003W, * * MSGHPSR0010W and "REASON CODE : 0041" * * in MSGHPSR0001I occurs * * when unloaded file is CS format. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** HP Load utility gets MSGHPSR0003W, MSGHPSR0010W and "REASON CODE : 0041" in MSGHPSR0001I occurs when unloaded file is CS format. Because the CS format has only specified fields of the DBD name and segment name in the header, and other fields are optional.
Problem conclusion
Temporary fix
Comments
-
HP Load utility has been modified as follows, Modify HPSRHDL6, HPSRHDL7, HPSRHDL8, HPSRRLD7, HPSRRLD8, HPSRHSL6, HPSRHSL7 and HPSRHSL8 to support the CS format that has only specified fields of the DBD name and segment name in the header, and other fields are optional * ======================== = DOCUMENTATION CHANGE = ======================== Documentation Changes: IMS High Performance Load User's Guide (SC27093800) should be changed as follows: ------------------------------------------------------------ Appendix C. Messages and Codes C.3. Messages C.3.1 High Performance Load Messages The following messages should be added ADD: |HPSR3674E DBDNAME dbdname IN CS HEADER DOES NOT MATCH DBD |SPECIFIED |Explanation: The dbdname in CS header must match dbdname |specified on EXEC parameters. |System Action: The Reload task issues user abend 3674. |Programmer Response: Correct the DBDNAME in CS header or |EXEC parameters, and rerun the job. |Problem Determination: None.
APAR Information
-
APAR number
PQ61147
-
Reported component name
IMS HIGH PERF L
-
Reported component ID
5655E0700
-
Reported release
110
-
Status
CLOSED UR1
-
PE
NoPE
-
HIPER
NoHIPER
-
Special Attention
NoSpecatt / Xsystem
-
Submitted date
2002-05-14
-
Closed date
2002-05-20
-
Last modified date
2002-06-05
-
APAR is sysrouted FROM one or more of the following:
-
APAR is sysrouted TO one or more of the following:
UQ66423
Modules/Macros
-
HPSRHALM HPSRHAL8 HPSRHDBD HPSRHDB8 HPSRHDLD HPSRHDL5 HPSRHDL6 HPSRHDL7 HPSRHDL8 HPSRHRPT HPSRHRP8 HPSRHSLD HPSRHSL6 HPSRHSL7 HPSRHSL8 HPSRMSGT HPSRRLDM HPSRRLD7 HPSRRLD8
Fix information
-
Fixed component name
IMS HIGH PERF L
-
Fixed component ID
5655E0700
Applicable component levels
-
R110 PSY UQ66423
UP02/05/22 P F205
Fix is available
-
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89F","label":"IMS HP Load"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"110"}]
Document Information
Modified date:
03 April 2021