Error description
When attempting to restart a PRF-controlled job after backing out of IMS V15 to a prior release, the restarted job generates the following error message along with ABEND U3630 : IRT039E NO IMSxx10 SUPPORT FOR IMS1510 EXTENDED RESTARTS. Additional issue found and addressed: When a PRF-controlled job restarts across release boundaries, PRF generates MSGIRT040I: IRT040I JOB RUN UNDER IMS xx10 RESTARTING UNDER IMS yy10. However, the version numbers are switched; the xx10 version is actually the version under which the job is restarting, and the yy10 version is actually the version under which the job was originally run.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: 1). All users of Program Restart Facility * * V2R2 who wish to run Program Restart * * Facility under IMS V15 QPP and attempt to * * restart an abended job after reverting to a * * prior version of IMS. * * * * 2). All users of Program Restart Facility * * who restart abended jobs on a different * * version of IMS. * **************************************************************** * PROBLEM DESCRIPTION: 1). When a job under PRF control abends * * in an IMS V15 QPP environment, and the * * restart of the job is attempted under a * * prior version of IMS, IRT039E NO * * IMSxx10 SUPPORT FOR IMS1510 EXTENDED * * RESTARTS is generated. The 'xx' in the * * 'IMSxx10' portion of the message will * * be replaced with the IMS version number * * of the IMS instance where the job is * * being restarted. The job then * * exeriences a U3630 abend. * * * * 2). When a job under PRF control abends * * and is restarted under a different * * version of IMS, IRT040I JOB RUN UNDER * * IMS xx10 RESTARTING UNDER IMS yy10 is * * generated. 'xx' is supposed to be the * * version of IMS where the job originally * * abended, while 'yy' is supposed to be * * the version of IMS where the job is * * restarting. These values were reversed. * **************************************************************** * RECOMMENDATION: Apply the PTF that corrects this APAR. * **************************************************************** 1). A table that defines IMS versions that support restart from prior or superseding IMS versions was updated to support IMS V15 QPP. However, that table was not propagated to version-dependent code in versions of IMS prior to IMS V15 QPP. 2). The version of IMS that the job abended under is retrieved from the x'18' log record being used to restart the job. The version of IMS that the job is restarting under is retrieved from the IMS SCD being used by the job. Instead of using the IMS SCD value to generate the restarting IMS version, the data from the x'18' log record was used. Similarly, the IMS SCD value was used, instead of the data from the x'18' log record, to determine the version of IMS under which the job abended.
Problem conclusion
1). Upon application of this PTF, jobs under PRF control that abend under IMS V15 QPP will successfully restart under a previous version of IMS. 2). Upon application of this PTF, the IRT040I message that is generated when a job is restarted under a different version of IMS from which the job originally abended, will report the correct original and restarting versions of IMS.
Temporary fix
Comments
APAR Information
APAR number
PI79910
Reported component name
IMS PGM RESTART
Reported component ID
5655E1400
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-04-12
Closed date
2017-04-18
Last modified date
2017-05-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI46496
Modules/Macros
IRTXRI09 IRTXRI10 IRTXRI11 IRTXRI12 IRTXRI13 IRTXRI14 IRTXRI15
Fix information
Fixed component name
IMS PGM RESTART
Fixed component ID
5655E1400
Applicable component levels
R220 PSY UI46496
UP17/04/19 P F704
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSAVHR","label":"IMS Program Restart Facility for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220"}]
Document Information
Modified date:
24 January 2022