A fix is available
APAR status
-
Closed as program error.
Error description
-
When an ACBGEN using LIU Advanced ACB Gen is followed by a compare with the affected ACBLIBs in 3 separate steps; the last step abends with an S0C4-11 in module FABLACT8. The compare is done using LIU FABLCOMP. The first 2 compares are OK.
Local fix
Problem summary
-
**************************************************************** * USERS AFFECTED: All IMS Library Integrity Utilities for * * z/OS, Version 1 Release 1 (FMID=H27P110) * * users who use DBD/PSB/ACB Compare utility * **************************************************************** * PROBLEM DESCRIPTION: ACB Compare abends with an S0C4-11 in * * module FABLACT8. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** ACB Compare abends while comparing two DMBs which have different numbers of the FIELD statements and the XDFLD statements, because the FIELD statement of one DMB is treated as a XDFLD statement incorrectly.
Problem conclusion
-
The FABLDMBx (x=5,6,7,8,9) modules are modified not to compare information about the XDFLD statement and information about the FIELD statement when the numbers of the FIELD statements of two DMBs are different.
Temporary fix
Comments
APAR Information
-
APAR number
PQ91326
-
Reported component name
IMS LIBR INTEG
-
Reported component ID
5655I4200
-
Reported release
110
-
Status
CLOSED PER
-
PE
NoPE
-
HIPER
NoHIPER
-
Special Attention
NoSpecatt / Xsystem
-
Submitted date
2004-07-13
-
Closed date
2004-07-30
-
Last modified date
2004-08-04
-
APAR is sysrouted FROM one or more of the following:
-
APAR is sysrouted TO one or more of the following:
UQ91198
Modules/Macros
-
FABLDMB5 FABLDMB6 FABLDMB7 FABLDMB8 FABLDMB9
Fix information
-
Fixed component name
IMS LIBR INTEG
-
Fixed component ID
5655I4200
Applicable component levels
-
R110 PSY UQ91198
UP04/08/02 P F407
Fix is available
-
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.