A fix is available
APAR status
Closed as program error.
Error description
When EXPORTABLE=YES and MULTIIMSID=YES are specified for HISTORY data set, the Export utility of DBHDA (DB Historical Data Analyzer) writes a wrong data set group number into flat records that are stored in the FABGEXPF data set.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: IBM IMS High Performance Pointer Checker for * * z/OS Version 3 Release 1 (FMID=HPC2310) * * users who run the Export Utility of DB * * Historical Data Analyzer (DBHDA). * **************************************************************** * PROBLEM DESCRIPTION: In this APAR, the following error (1) * * is fixed and the new function (2) is * * added to Export Utility of DBHDA. * * * * (1) Incorrect values in flat records * * * * When HISTORY data set with * * MULTIIMSID=YES option is used in * * Export Utility, Export Utility writes * * incorrect values in flat records. * * * * (2) New format of segment hierarchical * * level in flat records * * * * Character format is supported in the * * field of a segment hierarchical level * * in flat records. * * This addresses FITS REQ MR0622091232. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** (1) Incorrect values in flat records When a HISTORY data set with MULTIIMSID=YES option is used in Export Utility, Export Utility writes incorrect values into the following fields in flat records. - DSGID (Data set Group identifier) - DSGIDCHR (Data set Group identifier in character format) - AVDBREC (Average database record length) - NO_OF_ROTNOHOM (The number of root segment occurrences in blocks other than HOME block) (2) New format of segment hierarchical level in flat records Character format is supported in a field of a segment hierarchical level in flat records. The field name of a segment hierarchical level in flat records is SEGLVL.
Problem conclusion
Documentation Changes: Note: The section numbers are those of the BookManager (BKMGR) book. The documentation is modified as follows: ============================================================== IMS High Performance Pointer Checker for z/OS, V3R1, User's Guide (SC19240100) ============================================================== >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 4.0 DB Histrical Data Analyzer >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> -------------------------------------------------------------- 4.3 Operating instructions for Export Utility 4.3.3 Input 4.3.3.3 FABGRECI data set 4.3.3.3.7 Field names -------------------------------------------------------------- The row of SEGLVL in Table 59. is modified as follows: Field name: SEGLVL Maximum length that can be specified: | C --> 2 X --> 1 P --> 0
Temporary fix
Comments
APAR Information
APAR number
PK89657
Reported component name
IMS POINTER CHE
Reported component ID
5655E0900
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2009-06-23
Closed date
2009-07-10
Last modified date
2009-08-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK48257
Modules/Macros
FABGXCB0 FABGXFLD FABGXXPE
| SC19240100 |
Fix information
Fixed component name
IMS POINTER CHE
Fixed component ID
5655E0900
Applicable component levels
R310 PSY UK48257
UP09/07/11 P F907
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89G","label":"IMS HP Pointer Checker"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0"}]
Document Information
Modified date: