A fix is available
APAR status
Closed as program error.
Error description
OPEN error ABEND013 occurs for the PROCCTL data set when HDPC runs as ULU region with MSGIEC141I This error occurs when the PROCCTL DD statements are concatenated as follows: //PROCCTL DD DISP=SHR,DSN=data set name(member name) // DD * some control statements here /*
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: IBM IMS High Performance Pointer Checker for * * z/OS Version 3 Release 1 (FMID=HPC2310) * * users who run HD Pointer Checker stand alone * * FABPMAIN job as IMS utility batch region * * (ULU). * **************************************************************** * PROBLEM DESCRIPTION: HD Pointer Checker (HDPC) gets * * ABEND013-4C while it is opening PROCCTL * * statements. This error occurs when * * DSN= data set name and a DD * instream * * data set are concatenated by mixture * * to the PROCCTL DD. * * For example, * * * * //PROCCTL DD DSN=dsname,... * * // DD * * * ... control statements * * * * This ABEND occurs only when HDPC runs * * as ULU batch region. It does not occur * * when HDPC runs as DLI or DBB region. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** When HDPC closes PROCCTL data sets, it does not release the buffer pool by FREEPOOL macro. Therefore HDPC gets ABEND013 when it opens the PROCCTL data set again.
Problem conclusion
The following module have been changed to fix the error: FABPMAIN
Temporary fix
Comments
APAR Information
APAR number
PK81415
Reported component name
IMS POINTER CHE
Reported component ID
5655E0900
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2009-02-26
Closed date
2009-03-02
Last modified date
2009-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK44473
Modules/Macros
FABPMAIN
Fix information
Fixed component name
IMS POINTER CHE
Fixed component ID
5655E0900
Applicable component levels
R310 PSY UK44473
UP09/03/04 P F903
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89G","label":"IMS HP Pointer Checker"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0"}]
Document Information
Modified date: