A fix is available
APAR status
Closed as program error.
Error description
Message IRT273E contains incorrect abend and return code. Additionally, customers should be informed that if STEPLIB/JOBLIB is authorized, and the application load library is also authorized, the IRTOPT library pointed to by the IRT#OPT member must also be authorized. If not, message IRT273E is issued followed by ABENDU4000.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Program Restart Facility V2R2. * **************************************************************** * PROBLEM DESCRIPTION: Message IRT273E contains incorrect * * abend and return code. * **************************************************************** * RECOMMENDATION: * **************************************************************** Message IRT273E contains incorrect abend and return code. Additionally, customers should be informed that if STEPLIB/JOBLIB is authorized, and the application load library is also authorized, the IRTOPT library pointed to by the IRT#OPT member must also be authorized. If not, message IRT273E is issued followed by ABENDU4000.
Problem conclusion
Code has been modified to correct message IRT273E
Temporary fix
Comments
APAR Information
APAR number
PI43925
Reported component name
IMS PGM RESTART
Reported component ID
5655E1400
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-06-26
Closed date
2016-03-09
Last modified date
2016-04-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI36000
Modules/Macros
IRTOPTR
Fix information
Fixed component name
IMS PGM RESTART
Fixed component ID
5655E1400
Applicable component levels
R220 PSY UI36000
UP16/03/21 P F603
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSV7D2","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: