APAR status
Closed as program error.
Error description
With parallel IO enabled, it is possible that all the afmMaxWorkerThreads are used and there are no threads to handle the parallel IO responses.
Local fix
Disable parallel IO
Problem summary
With parallel IO enabled, it is possible that all the afmMaxWorkerThreads are used and there are no threads to handle the parallel IO responses.
Problem conclusion
Benefits of the solution: No deadlock. Work around: Disable parallel IO Problem trigger: AFM with parallel IO under heavy workload Symptom: Deadlock Platforms affected: All OS environments Functional Area affected: AFM and AFM DR Customer Impact: Critical
Temporary fix
Comments
APAR Information
APAR number
IJ27366
Reported component name
SPEC SCALE STD
Reported component ID
5737F33AP
Reported release
505
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-09-02
Closed date
2020-09-02
Last modified date
2020-09-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE STD
Fixed component ID
5737F33AP
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY","label":"IBM Spectrum Scale"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"505","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date:
03 September 2020