IBM Support

Security Bulletin: IBM Systems Director (ISD) Storage Control is affected by vulnerabilities in IBM Websphere Application Server (WAS), OpenSSL and IBM Java Runtime.

Created by Vern Yetzer on
Published URL:
https://www.ibm.com/support/pages/node/630947
630947

Security Bulletin


Summary

There are vulnerabilities addressed in IBM WAS, IBM Runtime Environment Java™Technology Edition, and OpenSSL that are used by ISD Storage Control. The Java issues were disclosed as part of the IBM Java updates for January 2017.

Vulnerability Details


CVEID: CVE-2016-2183
DESCRIPTION:
OpenSSL could allow a remote attacker to obtain sensitive information, caused by an error in the DES/3DES cipher, used as a part of the SSL/TLS protocol. By capturing large amounts of encrypted traffic between the SSL/TLS server and the client, a remote attacker able to conduct a man-in-the-middle attack could exploit this vulnerability to recover the plaintext data and obtain sensitive information. This vulnerability is known as the SWEET32 Birthday attack.
CVSS Base Score: 3.7
CVSS Temporal Score: See https://exchange.xforce.ibmcloud.com/vulnerabilities/116337 for the current score
CVSS Environmental Score*: Undefined
CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N)

CVEID: CVE-2016-5546
DESCRIPTION:
An unspecified vulnerability related to the Libraries component has no confidentiality impact, high integrity impact, and no availability impact.
CVSS Base Score: 7.5
CVSS Temporal Score: See https://exchange.xforce.ibmcloud.com/vulnerabilities/120869 for the current score
CVSS Environmental Score*: Undefined
CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N)

CVEID: CVE-2016-5548
DESCRIPTION: An unspecified vulnerability related to the Libraries component could allow a remote attacker to obtain sensitive information resulting in a high confidentiality impact using unknown attack vectors.
CVSS Base Score: 6.5
CVSS Temporal Score: See https://exchange.xforce.ibmcloud.com/vulnerabilities/120864 for the current score
CVSS Environmental Score*: Undefined
CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N)

CVEID: CVE-2016-5549
DESCRIPTION: An unspecified vulnerability related to the Libraries component could allow a remote attacker to obtain sensitive information resulting in a high confidentiality impact using unknown attack vectors.
CVSS Base Score: 6.5
CVSS Temporal Score: See https://exchange.xforce.ibmcloud.com/vulnerabilities/120863 for the current score
CVSS Environmental Score*: Undefined
CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N)

CVEID: CVE-2016-5547
DESCRIPTION:
An unspecified vulnerability related to the Libraries component could allow a remote attacker to cause a denial of service resulting in a low availability impact using unknown attack vectors.
CVSS Base Score: 5.3
CVSS Temporal Score: See https://exchange.xforce.ibmcloud.com/vulnerabilities/120871 for the current score
CVSS Environmental Score*: Undefined
CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L)



CVEID: CVE-2016-8919
DESCRIPTION:
IBM WebSphere Application Server may be vulnerable to a denial of service, caused by allowing serialized objects from untrusted sources to run and cause the consumption of resources.
CVSS Base Score: 5.9
CVSS Temporal Score: See https://exchange.xforce.ibmcloud.com/vulnerabilities/118529 for the current score
CVSS Environmental Score*: Undefined
CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H)

Affected Products and Versions

From the IBM Systems Director command line enter smcli lsver to determine the level of IBM Systems Director installed.

Affected Product and Version(s)Product and Version shipped as a component
IBM System Director Storage Control 4.2.6IBM Systems Director 6.3.5
IBM System Director Storage Control 4.2.7IBM Systems Director 6.3.6
IBM System Director Storage Control 4.2.8IBM Systems Director 6.3.7

Remediation/Fixes

To resolve this issue follow the instructions in table below.

Affected Product and Version(s)Remediation Instructions
IBM System Director Storage Control 4.2.6Technote 812452926 in the Support Portal
IBM System Director Storage Control 4.2.7Technote 812452926 in the Support Portal
IBM System Director Storage Control 4.2.8Technote 812452926 in the Support Portal

IBM Systems Director Storage Control versions pre-4.2.6 are unsupported and will not be fixed. IBM recommends upgrading to a fixed, supported version of the product.

Workarounds and Mitigations

None

Get Notified about Future Security Bulletins

References

Off

Change History

12 April, 2017 : Original version published

*The CVSS Environment Score is customer environment specific and will ultimately impact the Overall CVSS Score. Customers can evaluate the impact of this vulnerability in their environments by accessing the links in the Reference section of this Security Bulletin.

Disclaimer

Review the IBM security bulletin disclaimer and definitions regarding your responsibilities for assessing potential impact of security vulnerabilities to your environment.

[{"Product":{"code":"SGZ2Z3","label":"IBM Systems Director"},"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Component":"Not Applicable","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"Version Independent","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
17 June 2018

UID

isg3T1025082