Flashes (Alerts)
Abstract
When using the SET TIMEZONE=d.hh command, message IEE308I SET TERM LENGTH ERROR will be received. Problem is described by APAR OA51568. Command will be properly executed if the MINUTES value is specified on the command, i.e. SET TIMEZONE=d.hh.00 . The circumvention to the IEE308I is to add the MINUTES value to the failing command.
Content
Specify MINUTES value on SET TIMEZONE command:
SET TIMEZONE=d.hh.00
SET TIMEZONE=W.03.00
[{"Product":{"code":"SWG90","label":"z\/OS"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":"5752SC1C5 - SUPERVISOR CONTROL","Platform":[{"code":"PF035","label":"z\/OS"}],"Version":"2.2","Edition":"","Line of Business":{"code":"LOB56","label":"Z HW"}}]