Problem

Maximo Asset Management does not use Common PMP (PMCOM) objects and attributes in 7.6 and higher versions. But they could still be seen in many tables when Maximo Asset Management is upgraded from 7.1 to 7.5 > 7.6 > 7.6.1:

Maxattribute

Maxattributecfg

Maxobject

Maxobjectcfg

Maxtable

Maxtablecfg

Maxview

Maxviewcfg

Maxviewcolumn

Maxviewcolumncfg

Maxdomain

Maxtabledomain

Maxpresentation

Synonymdomain

CrossoverDomain

Alndomain

Maxservice

Maxrelationship

Maxmenu

Maxapps

Maxmodules

Maxlabels

Maxifacein

Maxifaceout

Maxextifacein

Maxextifaceout

Maxintobject

Maxintobjdetail

Maxintobjalias

Maxintobjcols

Maxconddetail

Maxpropvalue

Reportlabel

Skdaction

Autokey

Sigoption

Applicationauth

Reportappauth

Appdoctype

Kpimain

Kpitrendcfg

Sctemplate

Condition

Query

Jobplan

Longdescription

Wfaction

Wfcondition

Action

Symptom

During an upgrade from Maximo Asset Management 7609 to Maximo Asset Management 7.6.1.1, you notice a series of objects and attributes with names with %PMCOM% in the database.  If the application was previously upgraded from 7.1 to 7.5 and then to 7.6, common PMP records are found in the database.  Running the Integrity Checker would produce warnings showing the tables that still have PMCOM records:

MXAA0442W -- Warning - BMXAA7109W -- Column INCIDENT.PMCOMRESOLUTION is mapped to domain PMCOMRESOLUTION, but is not defined the same. INCIDENT.PMCOMRESOLUTION is ALN. PMCOMRESOLUTION is UPPER. Correct the data and try again. 
BMXAA0442W -- Warning - BMXAA7109W -- Column PMCOMSR.PMCOMRESOLUTION is mapped to domain PMCOMRESOLUTION, but is not defined the same. PMCOMSR.PMCOMRESOLUTION is ALN. PMCOMRESOLUTION is UPPER. Correct the data and try again.
BMXAA0442W -- Warning - BMXAA7109W -- Column PMCOMSR.PMCOMTYPE is mapped to domain PMPTYPE, but is not defined the same. PMCOMSR.PMCOMTYPE is ALN. PMPTYPE is UPPER. Correct the data and try again. 
BMXAA0442W -- Warning - BMXAA7109W -- Column PROBLEM.PMCOMRESOLUTION is mapped to domain PMCOMRESOLUTION, but is not defined the same. PROBLEM.PMCOMRESOLUTION is ALN. PMCOMRESOLUTION is UPPER. Correct the data and try again.
BMXAA0442W -- Warning - BMXAA7109W -- Column SR.PMCOMRESOLUTION is mapped to domain PMCOMRESOLUTION, but is not defined the same. SR.PMCOMRESOLUTION is ALN. PMCOMRESOLUTION is UPPER. Correct the data and try again.
BMXAA0442W -- Warning - BMXAA7109W -- Column TICKET.PMCOMRESOLUTION is mapped to domain PMCOMRESOLUTION, but is not defined the same. TICKET.PMCOMRESOLUTION is ALN. PMCOMRESOLUTION is UPPER. Correct the data and try again.
However, these warnings can be resolved by changing the affected attributes' maxtype to UPPER.

Document Location

Worldwide

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSLKT6","label":"IBM Maximo Asset Management"},"ARM Category":[{"code":"a8m50000000CbD5AAK","label":"Upgrade"},{"code":"a8m50000000CbDAAA0","label":"Upgrade-\u003EIntegrity Checker"}],"ARM Case Number":"","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1.0;7.5.0;7.6.0;7.6.1","Line of Business":{"code":"LOB77","label":"Automation Platform"}},{"Product":{"code":"SSRHPA","label":"IBM Maximo Application Suite"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Component":" ","Platform":[{"code":"","label":""}],"Version":"","Edition":"","Line of Business":{"code":"LOB77","label":"Automation Platform"}},{"Product":{"code":"SSWT9A","label":"IBM Control Desk"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Component":" ","Platform":[{"code":"","label":""}],"Version":"","Edition":"","Line of Business":{"code":"LOB77","label":"Automation Platform"}}]

Log InLog in to view more of this document

This document has the abstract of a technical article that is available to authorized users once you have logged on. Please use Log in button above to access the full document. After log in, if you do not have the right authorization for this document, there will be instructions on what to do next.

Document Information

Modified date:
18 September 2025

UID

ibm16261511