Problem
Maximo Asset Management does not use Common PMP (PMCOM) objects and attributes in 7.6 and higher versions. But they could still be seen in many tables when Maximo Asset Management is upgraded from 7.1 to 7.5 > 7.6 > 7.6.1:
Maxattribute
Maxattributecfg
Maxobject
Maxobjectcfg
Maxtable
Maxtablecfg
Maxview
Maxviewcfg
Maxviewcolumn
Maxviewcolumncfg
Maxdomain
Maxtabledomain
Maxpresentation
Synonymdomain
CrossoverDomain
Alndomain
Maxservice
Maxrelationship
Maxmenu
Maxapps
Maxmodules
Maxlabels
Maxifacein
Maxifaceout
Maxextifacein
Maxextifaceout
Maxintobject
Maxintobjdetail
Maxintobjalias
Maxintobjcols
Maxconddetail
Maxpropvalue
Reportlabel
Skdaction
Autokey
Sigoption
Applicationauth
Reportappauth
Appdoctype
Kpimain
Kpitrendcfg
Sctemplate
Condition
Query
Jobplan
Longdescription
Wfaction
Wfcondition
Action
Symptom
During an upgrade from Maximo Asset Management 7609 to Maximo Asset Management 7.6.1.1, you notice a series of objects and attributes with names with %PMCOM% in the database. If the application was previously upgraded from 7.1 to 7.5 and then to 7.6, common PMP records are found in the database. Running the Integrity Checker would produce warnings showing the tables that still have PMCOM records:
MXAA0442W -- Warning - BMXAA7109W -- Column INCIDENT.PMCOMRESOLUTION is mapped to domain PMCOMRESOLUTION, but is not defined the same. INCIDENT.PMCOMRESOLUTION is ALN. PMCOMRESOLUTION is UPPER. Correct the data and try again.
MXAA0442W -- Warning - BMXAA7109W -- Column INCIDENT.PMCOMRESOLUTION is mapped to domain PMCOMRESOLUTION, but is not defined the same. INCIDENT.PMCOMRESOLUTION is ALN. PMCOMRESOLUTION is UPPER. Correct the data and try again.
BMXAA0442W -- Warning - BMXAA7109W -- Column PMCOMSR.PMCOMRESOLUTION is mapped to domain PMCOMRESOLUTION, but is not defined the same. PMCOMSR.PMCOMRESOLUTION is ALN. PMCOMRESOLUTION is UPPER. Correct the data and try again.
BMXAA0442W -- Warning - BMXAA7109W -- Column PMCOMSR.PMCOMTYPE is mapped to domain PMPTYPE, but is not defined the same. PMCOMSR.PMCOMTYPE is ALN. PMPTYPE is UPPER. Correct the data and try again.
BMXAA0442W -- Warning - BMXAA7109W -- Column PROBLEM.PMCOMRESOLUTION is mapped to domain PMCOMRESOLUTION, but is not defined the same. PROBLEM.PMCOMRESOLUTION is ALN. PMCOMRESOLUTION is UPPER. Correct the data and try again.
BMXAA0442W -- Warning - BMXAA7109W -- Column SR.PMCOMRESOLUTION is mapped to domain PMCOMRESOLUTION, but is not defined the same. SR.PMCOMRESOLUTION is ALN. PMCOMRESOLUTION is UPPER. Correct the data and try again.
BMXAA0442W -- Warning - BMXAA7109W -- Column TICKET.PMCOMRESOLUTION is mapped to domain PMCOMRESOLUTION, but is not defined the same. TICKET.PMCOMRESOLUTION is ALN. PMCOMRESOLUTION is UPPER. Correct the data and try again.
However, these warnings can be resolved by changing the affected attributes' maxtype to UPPER.
Document Location
Worldwide
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSLKT6","label":"IBM Maximo Asset Management"},"ARM Category":[{"code":"a8m50000000CbD5AAK","label":"Upgrade"},{"code":"a8m50000000CbDAAA0","label":"Upgrade-\u003EIntegrity Checker"}],"ARM Case Number":"","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1.0;7.5.0;7.6.0;7.6.1","Line of Business":{"code":"LOB77","label":"Automation Platform"}},{"Product":{"code":"SSRHPA","label":"IBM Maximo Application Suite"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Component":" ","Platform":[{"code":"","label":""}],"Version":"","Edition":"","Line of Business":{"code":"LOB77","label":"Automation Platform"}},{"Product":{"code":"SSWT9A","label":"IBM Control Desk"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Component":" ","Platform":[{"code":"","label":""}],"Version":"","Edition":"","Line of Business":{"code":"LOB77","label":"Automation Platform"}}]
Log InLog in to view more of this document
This document has the abstract of a technical article that is available to authorized users once you have logged on. Please use Log in button above to access the full document. After log in, if you do not have the right authorization for this document, there will be instructions on what to do next.
Was this topic helpful?
Document Information
Modified date:
18 September 2025
UID
ibm16261511