IBM Support

PH28476: NEW LOAD UTILITY OPTION UPDMAXASSIGNEDVAL YES|NO

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • This APAR delivers a new LOAD utility option
    UPDMAXASSIGNEDVAL YES|NO.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All Db2 11 for z/OS and Db2 12 for z/OS                      *
    * users of the LOAD utility.                                   *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * This enhancement provides a new                              *
    * keyword UPDMAXASSIGNEDVAL option on                          *
    * the LOAD utility with operands YES and                       *
    * NO, which will allow customers to                            *
    * specify whether Db2 12 should update                         *
    * MAXASSIGNEDVAL for user-provided                             *
    * identity column value input.                                 *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    With Db2 12, the LOAD utility updates the MAXASSIGNEDVAL for
    user-provided input. This is in contrast to Db2 11, which did
    not maintain MAXASSIGNEDVAL for such LOAD scenarios. Db2 12
    users presently have no way to revert to the prior behavior.
    

Problem conclusion

Temporary fix

Comments

  • A new keyword UPDMAXASSIGNEDVAL with options YES or NO will
    be added to the LOAD utility. This will allow users to decide
    whether to maintain and update the SYSIBM.SYSSEQUENCE
    catalog MAXASSIGNEDVAL value relating to the identity columns
    based on the input identity column values loaded.
    PH28476 introduces the following changes to externals:
    LOAD utility syntax diagram change:
             .-UPDMAXASSIGNEDVAL-YES-.
    >>-LOAD----------------------------->
             '-UPDMAXASSIGNEDVAL-NO--'
    UPDMAXASSIGNEDVAL
         Specifies whether LOAD updates the MAXASSIGNEDVAL column
         in the SYSIBM.SYSSEQUENCES catalog table for identity
         columns.
    YES
         Specifies that LOAD updates MAXASSIGNEDVAL when the
         loaded value for the identity column is greater or
         smaller than the current value of MAXASSIGNEDVAL,
         depending on whether ascending or descending sequencing
         is in use. YES is the default.
    NO
         Specifies that LOAD does not update MAXASSIGNEDVAL
         regardless of the value of the loaded identity column.
    Special note
         Although you can specify this option in Db2 11,
         UPDMAXASSIGNEDVAL has no effect until Db2 12.
    IBM Knowledge Center is updated for this change:
    http://www.ibm.com/support/knowledgecenter/SSEPEK_11.0.0
    http://www.ibm.com/support/knowledgecenter/SSEPEK_12.0.0
    

APAR Information

  • APAR number

    PH28476

  • Reported component name

    DB2 OS/390 & Z/

  • Reported component ID

    5740XYR00

  • Reported release

    B10

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-08-13

  • Closed date

    2020-08-27

  • Last modified date

    2020-09-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI71292 UI71293

Modules/Macros

  • DSNUGPRT DSNURWI
    

Fix information

  • Fixed component name

    DB2 OS/390 & Z/

  • Fixed component ID

    5740XYR00

Applicable component levels

  • RC10 PSY UI71293

       UP20/08/29 P F008

  • RB10 PSY UI71292

       UP20/08/29 P F008

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEPEK","label":"Db2 for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"11.0","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: