Error description

  • APAR PH23939 introduced changes to the IMS PA transit engine
    to deal with mismatched MSGORGTK in program-switch chains. As a
    result of these changes a loop condition, and possible S0C4
    abend were observed around IPI4PROC + 1FF6 when traversing the
    program-switch chain at transaction termination.
    
    Another offset of the ABENDS0C4 was seen at x'EFBE' into
    IPI4PROC.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Performance Analyzer V4.4       *
    ****************************************************************
    * PROBLEM DESCRIPTION: Loop or possible S0C4 abend processing  *
    *                      program switch chain                    *
    ****************************************************************
    APAR PH23939 introduced changes to the IMS PA transit engine
    to deal with mismatched MSGORGTK in program-switch chains.
    As a result of these changes a loop condition, and possible
    S0C4 abend, were observed around IPI4PROC+1FF6 when
    traversing the program-switch chain at transaction
    termination.
    

Problem conclusion

  • 1. The processing changes implemented by PH23939 are deprecated
       by APAR PH27507 which introduces new logic for dealing with
       mismatched MSGORGTK.
    
    2. Message IPI0150E will still be issued when the first
       mismatched MSGORGTK is encountered, but the IMS PA
       processing logic will switch to PROGRAMSWITCH(NO) and not
       attempt to re-link program-switch messages. Message
       IPI0335W will be issued to indicate that the change in
       processing logic has taken place.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH27507

  • Reported component name

    IMS PERF ANALYZ

  • Reported component ID

    5655E1500

  • Reported release

    440

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-07-15

  • Closed date

    2020-07-27

  • Last modified date

    2020-08-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI70720

Modules/Macros

  • IPIGGET  IPIIPROC IPIMSGT  IPISAPAR IPIZRFEV
    

Fix information

  • Fixed component name

    IMS PERF ANALYZ

  • Fixed component ID

    5655E1500

Applicable component levels

  • R440 PSY UI70720

       UP20/07/30 P F007

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A2","label":"IMS Performance Analyzer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"440"}]

Document Information

Modified date:
03 October 2020