PI49907: DYNAMIC ALLOCATION FAILURE WITH RSN=035C0010 IN CREATE IMAGE COPY FUNCTION

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Dynamic Allocation failure with RSN=035C0010 is detected in the
    Create Image Copy function of IMS HP Image Copy when unit name
    in Image Copy record of DBRC RECON is not real unit name in the
    system.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 4 Release 2 users ( FMID=H1J0420 )   *
    ****************************************************************
    * PROBLEM DESCRIPTION: The Create Image Copy (CRC) function    *
    *                      of IMS HP Image Copy terminates with    *
    *                      ABEND U3916 ( ABENDU3916 ) and message  *
    *                      FABJ3916E ( MSGFABJ3916E ) when all of  *
    *                      the following conditions are            *
    *                      satisfied:                              *
    *                      -The process runs with DBRC=Y, and      *
    *                       IGNORCAT=N.                            *
    *                      -Input image copy data set is           *
    *                       expected to be allocated dynamically   *
    *                       in the process.                        *
    *                      -CATDS option is defined in DBRC        *
    *                       RECON.                                 *
    *                      -Input image copy data set is           *
    *                       registered in DBRC, and its UNIT       *
    *                       name information is incorrect.         *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    The Create Image Copy (CRC) function of IMS HP Image Copy
    terminates with ABEND U3916 ( ABENDU3916 ) and message
    FABJ3916E ( MSGFABJ3916E ) when all of the following conditions
    are satisfied:
    -The process runs with DBRC=Y, and IGNORCAT=N.
    -Input image copy data set is expected to be allocated
     dynamically in the process.
    -CATDS option is defined in DBRC RECON.
    -Input image copy data set is registered in DBRC, and its UNIT
     name information is incorrect.
    
    The cause of a problem is that IMS HP Image Copy allocates the
    input image copy data set dynamically by using UNIT name
    information of the image copy record in DBRC RECON instead of
    catalog information, but it is not validated name.
    Therefore, DYNALLOC process fails with RC=1E and RSN=035C0010.
    

Problem conclusion

  • By this APAR, the Create Image Copy function refers to catalog
    for information about the input image copy data set, and uses
    it as the parameter of the DYNALLOC request when CATDS is
    defined in DBRC and the input image copy data set is cataloged.
    The Create Image Copy function still uses information in image
    copy record in DBRC.
    
    When the Create Image Copy function runs under one following
    conditions, information in image copy record in DBRC uses as
    the parameter of DYNALLOC:
    -NOCATDS is defined.
    -Image Copy data set is not cataloged.
    -IGNORCAT=Y is requested.
    
    ========================
    = DOCUMENTATION CHANGE =
    ========================
    IMS High Performance Image Copy for z/OS Version 4 Release 2
    User's Guide SC19-2756-01 ( SC19275601 ) should be changed as
    follows:
    
    Part 6. Troubleshooting
    Chapter 20. Messages and codes Messages
    | FABJ0236W mac-name    MACRO FAILED WITH  RC=nnnnnnnn
    | REASON=nnnnnnnn
    | Explanation:  The indicated macro failed with the return and
    | the reason codes.
    | System action: IMS HP Image Copy continues processing.
    
    | User response: None.
    
    User Guide Updates: Tech doc will be provided to IBM
    documentation group to be posted on the Web site.
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    PI49907

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-10-05

  • Closed date

    2015-11-02

  • Last modified date

    2015-12-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI32600

Modules/Macros

  • FABJCRC0 FABJDALC FABJMSGC
    

Publications Referenced
SC19275601    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R420 PSY UI32600

       UP15/11/05 P F511 Ž

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.