IBM Support

PH22031: HPIC ABEND S013-E1 WITH LBI ENABLED

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • HPIC Abend S013-E1 With LBI Enabled
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 4 Release 2 users ( FMID=H1J0420 )   *
    ****************************************************************
    * PROBLEM DESCRIPTION: Create Image Copy (CRC) function of IMS *
    *                      HP Image Copy terminates with ABEND     *
    *                      S013 ( ABEND013 ) when using input      *
    *                      image copy data set that is created     *
    *                      with Large Block Interface (LBI).       *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    Create Image Copy (CRC) function of IMS HP Image Copy terminates
    with ABEND S013 ( ABEND013 ) when using input image copy data
    set that is created with Large Block Interface (LBI).  IMS HP
    Image Copy does not set BLKSIZE=0 in OS control block for
    input image copy data set that is created with LBI.
    

Problem conclusion

  • Copy Image Copy function process sets BLKSIZE=0 for using
    input image copy data sets that are created as LBI.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH22031

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-02-12

  • Closed date

    2020-02-18

  • Last modified date

    2020-03-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI67957

Modules/Macros

  • FABJCRC0
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R420 PSY UI67957

       UP20/02/20 P F002

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"4.2.0","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: