Error description

  • HPIC code fix for obtained storage for saving volume serial
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 4 Release 2 users ( FMID=H1J0420 )   *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR fixes the following problems  *
    *                      of IMS HP Image Copy.                   *
    *                                                              *
    *                      - Image Copy function terminates with   *
    *                        ABEND S0C4 ( ABEND0C4 ) when the      *
    *                        image copy data set is allocated on   *
    *                        multiple volumes whose volume count   *
    *                        exceeds 48.                           *
    *                                                              *
    *                      - By the FDUMP process of Advanced      *
    *                        Image Copy Services, incorrect volume *
    *                        information is used for the primary   *
    *                        image copy data set.                  *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This APAR fixes the following problems of IMS HP Image Copy.
    
    - Image Copy function terminates with ABEND S0C4 ( ABEND0C4 )
      when the image copy data set is allocated on multiple volumes
      whose volume count exceeds 48.
    
      The cause of the problem is that IMS HP Image Copy obtains
      storage for saving volume serial number which can only keep 48
      volumes. When more than 48 volumes are needed for a image copy
      data set, IMS HP Image Copy tries to store information beyond
      the obtained storage boundary. As the result, the process
      terminates with ABEND S0C4.
    
    - By the FDUMP process of Advanced Image Copy Services,
      incorrect volume information is used for the primary image
      copy data set.
    
      IMS HP Image Copy overrides the volume information for the
      primary image copy data set by ones of the shadow data set.
    
      If the volume information of the shadow data set is not proper
      for the unit of the primary image copy data set, IMS HP Image
      Copy can not create the primary image copy data set.
    

Problem conclusion

  • By this APAR, IMS HP Image Copy has been changed to obtain
    storage which can store volume names up to maximum volume
    count(255).
    
    Also, IMS HP Image Copy has been modified to use the volume
    information of the primary image copy data set correctly.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI94253

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-02-27

  • Closed date

    2018-03-08

  • Last modified date

    2018-04-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI54329

Modules/Macros

  • FABJDFCA FABJDFCB FABJDFC2 FABJDFC3 FABJDFC4
    FABJDFC5 FABJDFC9 FABJDOPN
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R420 PSY UI54329

       UP18/03/10 P F803

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.