A fix is available
APAR status
Closed as new function.
Error description
When clients do not allow access to datasets in the MVS linklist. Explicit attempts to access SYS1.LINKLIB will cause an abend913.This change will ensure programs don't explicitly reference SYS1.LINKLIB, but use the implicit form of the call instead.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: IMS Database Repair Facility for z/OS * * Version 1 Release 2 * **************************************************************** * PROBLEM DESCRIPTION: DB Repair references SYS1.LINKLIB to * * execute system utilities. RACF * * protection on SYS1.LINKLIB may cause * * DBRF to fail Abend 913. * **************************************************************** * RECOMMENDATION: * **************************************************************** System utilities such as IDCAMS and IEHLIST are executed in DBRF using the TSO command "CALL 'SYS1.LINKLIB(name)' ". This method works only if the SYS1.LINKLIB data set is accessible to the user with READ access. When the RACF accesss is EXECUTE, this command form will fail.
Problem conclusion
Temporary fix
Comments
Changed all system utility references to use the TSO command form "CALL *(name) " requesting the utilities to be loaded from the standard z/OS library sequence. RACF authority of EXECUTE is sufficient for this method.
APAR Information
APAR number
PK45314
Reported component name
IMS DATABASE RE
Reported component ID
5655E0300
Reported release
120
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2007-05-16
Closed date
2007-08-15
Last modified date
2007-09-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK28265
Modules/Macros
FABZDATA FABZMAIN
Fix information
Fixed component name
IMS DATABASE RE
Fixed component ID
5655E0300
Applicable component levels
R120 PSY UK28265
UP07/08/17 P F708
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"1.2.0","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: