IBM Support

PK91965: THE APAR CORRECTS THE PROBLEM THAT HPIC DOES NOT UNAUTHORIZE SOME DBD IF DBALL=(Y,Y) IS REQUESTED.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The APAR corrects the HPIC problem that HPIC does not
    unauthorize some DBD if DBALL=(Y,Y) is request.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 4 Release 1 users ( FMID=H1J0410 )   *
    ****************************************************************
    * PROBLEM DESCRIPTION: HPIC Image Copy function does not       *
    *                      unauthorize the database of DSG when    *
    *                      all of the following conditions are     *
    *                      satisfied:                              *
    *                      - DBRC=Y is specified.                  *
    *                      - DBALL=(Y,Y) is specified.             *
    *                      - FASTIC=(,COPY) or FASTIC=(,DUMP) is   *
    *                        specified.                            *
    *                      - Input database is DL/I DB and         *
    *                        registered in the DBRC RECON.         *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    HPIC Image Copy function does not unauthorize the database of
    DSG when all of the following conditions are satisfied:
    - DBRC=Y is specified.
    - DBALL=(Y,Y) is specified.
    - FASTIC=(,COPY) or FASTIC=(,DUMP) is specified.
    - Input database is DL/I DB and registered in the DBRC RECON.
    
    The cause of this problem is that HPIC mishandles the status of
    authorization that is stored in HPIC control block.
    

Problem conclusion

  • FABJDMPN, FABJDPSN and FABJDFCN have been modified to correctly
    set the flag of HPIC control block that is managed for status
    of authorization to DBRC RECON.
    
    The following modules have been reassembled.
      FABJDMP7  FABJDMP8  FABJDMP9  FABJDMPA  FABJDMPB
      FABJDPS7  FABJDPS8  FABJDPS9  FABJDPSA  FABJDPSB
      FABJDFC7  FABJDFC8  FABJDFC9  FABJDFCA  FABJDFCB
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK91965

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2009-07-21

  • Closed date

    2009-09-02

  • Last modified date

    2009-10-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK49770

Modules/Macros

  • FABJDFCA FABJDFCB FABJDFCN FABJDFC7 FABJDFC8
    FABJDFC9 FABJDMPA FABJDMPB FABJDMPN FABJDMP7 FABJDMP8 FABJDMP9
    FABJDPSA FABJDPSB FABJDPSN FABJDPS7 FABJDPS8 FABJDPS9
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R410 PSY UK49770

       UP09/09/11 P F909

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"4.1.0","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 December 2020