Error description
A STAGE_1_OUT DOES NOT INCLUDE THE PARLIM PARAMETER OF THE TRANSACT MACRO IF A VALUE WAS NOT SPECIFIED OR IF THE VALUE HAD BEEN SPECIFIED IN DATA DICTIONARY AS 0 ( ZERO ). IMS RELEASES UP TO, AND INCLUDING, 2.2 WOULD DEFAULT THE PARLIM VALUE TO 0 WHEN NO VALUE WAS SPECIFIED. PARLIM=0 MEANT THAT IMS WILL ALLOW THE TRANSACTION TO BE SCHEDULED IN ONLY ONE REGION AT A TIME. IMS RELEASE 3.1 ( 566540801 R102 ) MODIFIED THE PARLIM PARM. IF NO VALUE IS SPECIFIED, THE DEFAULT IS ' NONE '. THIS HAS THE SAME MEANING AS THE PREVIOUS DEFAULT OF 0. HOWEVER, 0 NOW HAS A DIFFERENT MEANING. PARLIM=0 INDICATES THAT ANY INPUT MESSAGE CAN CAUSE A NEW REGION TO BE SCHEDULED BECAUSE THE SCHEDULING CONDITION WILL ALWAYS BE MET. THIS MEANS THAT DICTIONARY MUST PASS PARLIM=0 TO IMS IN THE STAGE_1_OUT IF THAT IS WHAT THE USER HAD SPECIFIED FOR THE TRANSACTION. THE TERMINAL USERS GUIDE, SH20918902 CHAP4 PAGE244, ALSO NEEDS TO BE CHANGED TO STATE THE VALID VALUES FOR PARLIM ARE 0 TO 32767. ANOTHER SYMPTOM OF THIS PROBLEM IS ' MSGDBD0025 W NO DATA WAS ADDED ' WHEN TRYING TO CHANGE THE PARLIM VALUE TO 0.
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
THIS APAR IS BEING CLOSED AS A SUGGESTION FOR FUTURE ADDITION TO THE DICTIONARY. ADDING THIS CHANGE WOULD REQUIRE REDESIGN OF THE DATA BASES.
APAR Information
APAR number
PL72372
Reported component name
OS/VS DATA DICT
Reported component ID
5740XXF00
Reported release
602
Status
CLOSED SUG
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
1990-10-30
Closed date
1991-05-24
Last modified date
1991-05-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSV7D2","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"602","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
28 November 2022