APAR status
Closed as program error.
Error description
CUSTOMER RAN AN RFG PROGRAM WITH TEST=Y IN THE COMMAND. IN THE CONTROL TRACE 1 MILLION+ BLANK LINES WERE GENERATED. CUSTOMER SENT RFG SOURCE OVER THE NET. USING THEIR PROGRAM, WE WERE ABLE TO RECREATE THE CUSTOMER OBSERVED PROBLEM. IT APPEARS THAT THERE IS A LOOP IN THE RFG CODE. IT WAS OBSERVED THAT WHEN RUNNING, THE RFG PROGRAM, THE % CPU WENT TO 90%+ FOR A PERIOD OF TIME. THIS GIVES ME THE IMPRESSION THAT A TIGHT LOOP IS BEING ENTERED IN THE RFG CODE. NO OTHER DOCUMENTATION IS REQUIRED OTHER THAN THE RFG SOURCE, WHICH WE ALREADY HAVE.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: ALL RELEASE 6 DATA DICTIONARY * * USERS OF RFG RELEASE 6 * **************************************************************** * PROBLEM DESCRIPTION: ONE OF THE AVAILABLE RFG FEATURES * * IS THE ABILITY OF THE USER TO * * DESIGNATE TABLES WITHIN RFG TO * * COLLECT DATA FOR LATER USE WITHIN * * RFG. WHEN RFG TRACE IS ACTIVE AND * * THE TABLE TO BE DUMPED CONTAINS * * MULTIPLE ENTRIES PER TABLE LINE * * WITH ONE OR MORE OF THE LINES * * BEING NULL (NO DATA) TRACE WILL * * GENERATE A MILLION + BLANK LINES * * THE CONTINUE NORMAL OPERATION. * **************************************************************** * RECOMMENDATION: APPLY THE FIX * **************************************************************** SEE PROBLEM DESCRIPTION
Problem conclusion
MODIFIED MODULE DBDRFABD TO CHECK WHETHER OR NOT THE CURRENT TABLE LINE IS OF LENGTH ZERO (NO DATA) AND BYPASS THE TRACE OF THAT LINE IF IT IS FOUND TO BE OF LENGTH ZERO.
Temporary fix
Comments
APAR Information
APAR number
PL04177
Reported component name
OS/VS DATA DICT
Reported component ID
5740XXF00
Reported release
660
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
1986-10-13
Closed date
1986-11-07
Last modified date
1987-02-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UL04746
Modules/Macros
DBDRFABD
Fix information
Fixed component name
OS/VS DATA DICT
Fixed component ID
5740XXF00
Applicable component levels
R660 PSY UL04746
UP86/11/21 P DLL5 F701