APAR status
Closed as program error.
Error description
The MEFG Comm and Server scripts processes wait PID command during Service shutdown. These commands generate errors which can be captured in the log, if standard error is redirected to the associate log.
Local fix
B2BISFG-51588
Problem summary
Users Affected: MEFG SWIFTNet users Problem Description: The MEFG Comm Server and MEFG SWIFTNet Server commands have their standard error redirected to the associated log files. Platforms Affected: All
Problem conclusion
Resolution Summary: A code fix is provided. Updated script to remove the command, wait $PID, from the STOP and STOPFORCE script action cases. This command is only relevant and successful when invoking script is the parent process for the PID. The STOP and STOPFORCE command are invoking in a subsequent shell than the PID owner. Delivered in: 5020603_15 6000005 5020605_3
Temporary fix
Comments
APAR Information
APAR number
IT32147
Reported component name
STR B2B INTEGRA
Reported component ID
5725D0600
Reported release
526
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-03-11
Closed date
2020-06-11
Last modified date
2020-10-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR B2B INTEGRA
Fixed component ID
5725D0600
Applicable component levels
[{"Line of Business":{"code":"LOB59","label":"Sustainability Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.6"}]
Document Information
Modified date:
14 October 2020