APAR status
Closed as documentation error.
Error description
It may happen that a load hangs and cannot be cancelled, for example using IBM Db2 Analytics Accelerator Studio. Such a situation could occur in case of an error in the stored procedure invoked by the load task. The error leads to a termination of the LOAD process on the accelerator. As a result the so-called pipe (used to transfer the data during unload/insert in the accelerator and the database) may be terminated before Db2luw can open it. This leads to a wait situation (Db2luw is waiting on the pipe and the accelerator is waiting on the termination of an INSERT statement) resulting in the load hang. A hotfix for maintenance level 7.5.1 is available: dwa-server-kit-7.5.1.0_dev_480-76829c5800.el7.ppc64le.rpm The issue will be fixed with maintenance level 7.5.2. Additional keywords: TS003652385 TS003761281 TS003497945 RTC#24817
Local fix
1. Wait until both accelerator and Db2luw clean up the situation (this may take a couple of hours) or 2. Restart the Accelerator using the IBM Db2 Analytics Accelerator Console
Problem summary
The "load in progress" logic has been changed to avoid the issue described in this APAR. The fix is part of maintenance level 7.5.2.
Problem conclusion
Upgrade your accelerator maintenance level to 7.5.2 or higher.
Temporary fix
Comments
APAR Information
APAR number
PH26790
Reported component name
ANYTCS ACCLTR Z
Reported component ID
5697DA700
Reported release
750
Status
CLOSED DOC
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-06-24
Closed date
2020-10-16
Last modified date
2020-10-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"750"}]
Document Information
Modified date:
19 October 2020