PM95607: DBFMIOS0 IS MISSING A CHECK FOR RBA AND CIDF WHEN USING FPBP64

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • DBFMIOS0 SEQ#57380000 checks 64 bit buffer and bypasses check
    for RBA and CIDF validity.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IMSFP V12 DEDB SDEP FPBP64=Y USERS.          *
    ****************************************************************
    * PROBLEM DESCRIPTION: DBFMIOS0 IS MISSING A CHECK FOR RBA     *
    *                      AND CIDF WHEN USING FPBP64.             *
    ****************************************************************
    * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF      *
    ****************************************************************
    DBFMIOS0 checks 64 bit buffer and bypasses check for RBA and
    and CIDF validity.  The validity checks for RBA and CIDF
    applicable under FPBP64 environment as well and it should be
    perform.
    

Problem conclusion

  • GEN:
    KEYWORDS:
    
    *** END IMS KEYWORDS ***
    
    The following changes have been made to correct reported
    problem:
    
    DBFMIOS0: Remove code that bypass RBA and CIDF validity check
              under FPBP64 environment.  Obtain the RBA and CIDF
              in buffer using 64 bit addressing and verify it.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM95607

  • Reported component name

    IMS V12

  • Reported component ID

    5635A0300

  • Reported release

    200

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-08-21

  • Closed date

    2013-10-24

  • Last modified date

    2013-11-04

  • APAR is sysrouted FROM one or more of the following:

    PM92552

  • APAR is sysrouted TO one or more of the following:

    UI11659

Modules/Macros

  •    DBFMIOS0
    

Fix information

  • Fixed component name

    IMS V12

  • Fixed component ID

    5635A0300

Applicable component levels

  • R200 PSY UI11659

       UP13/10/31 P F310

Fix is available