A fix is available
APAR status
Closed as program error.
Error description
The attributes being used to create the EMCS console causes the `Health Checker for z/OS` to issue a warning that the console will be processing a lot of message traffic, possibly unnecessarily.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Cloning Tool. * **************************************************************** * PROBLEM DESCRIPTION: The attributes being used to create * * the EMCS console causes the `Health * * Checker for z/OS` to issue a warning * * that the console will be processing a * * lot of message traffic, possibly * * unnecessarily. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PK32979
Reported component name
DB2 CLONING TOO
Reported component ID
5655N1000
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2006-10-13
Closed date
2006-10-27
Last modified date
2006-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CKZ00117 CKZ00451
Fix information
Fixed component name
DB2 CLONING TOO
Fixed component ID
5655N1000
Applicable component levels
R110 PSY UK19205
UP06/11/09 P F611
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.