A fix is available
APAR status
Closed as program error.
Error description
Traceback information in CEEDUMP does not contain all statement numbers when compiled TEST(SEP(DSNAME))
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V5 and later * * releases compiling and running programs * * compiled with the TEST(SEPARATE(DSNAME)) * * option. * **************************************************************** * PROBLEM DESCRIPTION: The traceback information in the * * CEEDUMP does not contain all statement * * numbers when the program is compiled * * TEST(SEP(DSNAME)). * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** During CEEDUMP processing, the COBOL runtime hit an error when locating statement numbers data from the debug information. The statement numbers therefore could not be printed in the traceback section of the CEEDUMP.
Problem conclusion
The COBOL runtime is corrected to print out the correct statement number in the trace back information in the CEEDUMP.
Temporary fix
Comments
APAR Information
APAR number
PH14328
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
7B0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-07-10
Closed date
2019-07-13
Last modified date
2019-08-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGZCEV4 IGZCMGEN IGZCMGUE IGZLLIBV IGZXAPI IGZXCDA IGZXD24 IGZXDIVZ IGZXDMR IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE IGZXLPKF IGZXLPKG IGZXPK2
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
R7B0 PSY UI64198
UP19/07/19 P F907
Fix is available