A fix is available
APAR status
Closed as program error.
Error description
On a Japanese system that uses DBCS characters the user invokes "call pgm01". The normal behavior is that the DDS screen is displayed. On the reported issue after the "call pgm01" is issued nothing is displayed. Only after resizing is the DDS screen is displayed. The issue is the same whether on a normal window or maximize.
Local fix
Resizing the PComm window display the DBCS DDS screen.
Problem summary
**************************************************************** * USERS AFFECTED: * * All IBM Personal Communications 5250 users * **************************************************************** * PROBLEM DESCRIPTION: * * Japanese DDS panel does not display data on the emulator * * screen. * **************************************************************** * RECOMMENDATION: * **************************************************************** When the user sends the command to display the table of data on the DDS panel, it fails to display the full table. If the user causes a refresh of the screen by moving/dragging the window size, the DDS panel data is displayed. This issue occurs due to the window repaint on the DDS screen panel.
Problem conclusion
PCSWS.EXE has been changed to refresh the DDS panel properly. Fix scheduled for PCOM 14.0.2 Refresh Pack (32-bit and 64-bit)
Temporary fix
Comments
APAR Information
APAR number
IT32831
Reported component name
PCOMM COMBO-ENG
Reported component ID
5639I7000
Reported release
E00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-05-12
Closed date
2020-07-06
Last modified date
2020-07-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
PCSWS
Fix information
Fixed component name
PCOMM COMBO-ENG
Fixed component ID
5639I7000
Applicable component levels
RE00 PSY
UP
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSEQ5Y","label":"Personal Communications"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"E00"}]
Document Information
Modified date: